MINIMUM CLEARANCE
Rear Vent
A: Side Wall to Unit
20” (508 mm)
20” (508 mm)
B: Back Wall to Unit
9” (229 mm)
10” (254 mm)
C: Corner Wall to Unit
11” (279 mm)
11” ( 279 mm)
D: Celing Height
56” (1422 mm)
56” ( 1422 mm)
E: Back Wall to Vent Pipe
13.7” ( 349 mm) 14.7” ( 374 mm)
F: Side Wall to Vent Pipe
25.7” ( 653 mm) 25.7” ( 653 mm)
G: Corner Wall to Vent Pipe
19.2” ( 486 mm) 19.2” ( 486 mm)
Front Wall - Furnishing
36” ( 915 mm)
36” ( 915 mm)
A
B
E
F
C
G
C
G
D
**
8"
2
"
8"
8"
16
"
A
B
E
F
C
G
C
G
D
**
8"
2
"
8"
8"
16
"
A
B
E
F
C
G
C
G
D
**
8"
2"
8"
8"
16
"
A
B
E
F
C
G
C
G
D
**
8
"
2"
8"
8"
16
"
Manufactured by:
RAIS A/S
Industrivej 20, DK-9900
Frederikshavn, Denmark
Rev: 5
Januar 23 - 2024
Model:
NEXO 100, 120, 140, 160, 185 USA
Solid Fuel Room Heater, For Use With Solid Wood Fuel Only
Emission Report no.
:
0138WS017E
Safety Report:
23-204
Model
Date of manufacture Month
Year
Serial no.
Made in Denmark
Tested to:
UL 1482-2022
Clearances to combustible surfaces
Parallel wall installation
Back wall
Side wall
Corner wall installation
Adjacent wall
Adjacent wall
** Rear/T
op vent option
Ceiling
Floor Protector
FLOOR PROTECTION:
Floor protection must be non-combustible material extending beneath the
stove, and to the front and sides from door opening and to the rear as indi-
cated. The floor protection is not required to have thermal protection (R=0)
Replace glass with only Rais authorized dealer supplied
ceramic glass
** Not Tested - NFPA Guidelines in USA,
U.S. ENVIRONMENTAL
PROTECTION AGENCY
Certified to comply with 2020
particulate emission standards using
crib wood. 1.1 g/hr, Method 28R
This wood heater needs periodic inspection and repair for proper operation.
Consult the owner’s manual for further information. It is against federal
regulations to operate this wood heater in a manner inconsistent with the
operating instructions in the owner’s manual.
** Non testé - NFPA Guidelines au USA
The appliance must not be installed in a factory-built
fireplace.
See further floor protection requirements
at bottom left corner of this label.
Floor protector must be under the pipe and 2”
(5cm) beyond each side for back venting.
Front
US
CLEARANCE TO COMBUSTIBLE WALLS
To find out whether the wall by which the stove is to be placed is combustible or not,
please contact your architect or the local building authorities.
If the floor is combustible, the stove must be placed on a non-combustible plate such
as steel, glass or stone.
It may be possible to reduce clearances to combustible walls using the methods de-
tailed in NFPA 211. Seek guidance and permission in your locality as permits or inspec-
tions may be required.
Clearances may only be reduced by means approved by regulatory authority
**:
Please refer to NFPA guidelines