CHIMNEY
RAIS stoves must be installed using a Class A UL 103 HT approved factory-built chim-
ney system or a code-approved masonry chimney with a flue liner. The chimney pipe
must be 6” in diameter.
The chimney must extend through the roof at least 3’ (1m), and 2’ (.6m) above any struc-
ture within 10’ (3m). The condition and height of the chimney are very important for
optimal use of the stove and we recommend a total minimum height of 10’ (3m).
Note the chimney connector pipe should not pass through an attic, roof space, closet,
concealed space, floor or ceiling.
Male
smok
e dir
ection
Female
Each chimney connector or stove pipe section, must be installed to each other with
the crimped end toward the stove. This prevents any amount of condensed or liquid
creosote from running down the outside of the pipe or the stove top.
Fasten the connector pipe to the flue collar with 3 self tapping/drilling screws through
the holes in the flue collar.
INSTALLATION
NOTE!
Do NOT connect this stive to a chimney flue or air distribution duct or any sys-
tem serving another appliance.
Never make “make-shift” compromises when installing the heater or shimney.
chimney connector should be in good condition and kept clean.