31
62
76
62
76
Vertical roof terminal type C31
Dimension of outflow pipe:
Ø100 / Ø150 Outlet connection piece on the stove
Ø100 / Ø150 Can be used for the entire chimney, or,
Ø130 / Ø200 Adapter can be used so that you can use
Ø130 / Ø200 after the adapter.
Outlet terminal
Ø130 / Ø200 Art. no. USDVC 130
Ø100 / Ø150
Art. no. USDVC 100
Minimum vertical length of outlet pipe 0.5m
Flue gas Limiter to Ø100/Ø150 is to be mounted along with the inner outlet connection
piece.
Vertical height < 1m
No limiter
Vertical height 1-2m
Ø62mm limiter
Vertical height > 2m
Ø76mm limiter