9
General Comments
This RAIS /
attika
product is an extremely effective convection gas stove with a sealed
combustion chamber for chimneys with a balanced draught. It is fitted with a burner
with the latest burner technology. It has a variable heat output because it uses a special
control system that makes it possible to use three burners for high output or one burner
for a lower output. One of the burners, called the "Main burner" is located in the centre
of the stove, the second and third burners, called the "Secondary burners" are located
behind the Main burner. The secondary burners can be switched on and off while the
stove is on.
Where there is a natural gas connection, the local gas supply conditions should be inves-
tigated to ensure that the gas composition and pressure suit the stove's settings.
If the stove is connected to bottled gas, only gas bottles fitted with a gas regulator (Low
pressure regulator) providing the correct gas pressure may be connected. For this reason,
gas bottles without a regulator must not be connected.
This stove must only be installed, set up and serviced by a Gas safe registered Engineer.
The installation must comply with local and national Building Regulations and Gas
Regulations and the user manual must be adhered to. The user manual should be left
with the customer, who should keep this for later use. The manual is necessary when the
stove is to be serviced.
Ensure that the chimney terminal is not blocked in any way and is free of vegetation
in the form of trees, bushes etc. and that objects are not resting against the chimney's
terminal or the protection around the terminal.
The door glass should always be cleaned before the stove is turned on and fingerprints
wiped as these can be burned into the glass.
The stove must not be used if the door glass is split, cracked, removed or if the
door is open. Do not use the stove if the door gasket is broken or worn.
This stove is designed for use in many different installation situations, which can be seen
in this manual. Only chimneys approved by RAIS /
attika
may be used with this prod-
uct. (see chimney section)
This stove is intended for chimneys with balanced draughts (Air intake and draught in
same chimney) so there is no need for any extra air supply for combustion.
This product is a heating appliance so the surfaces become very hot and should
not be touched during use. It is therefore recommended that you use an ap-
proved stove screen to protect children, vulnerable adults, older people and
persons with reduced mobility in the same area as the stove.
Keep curtains, washing, furniture etc. at a minimum distance of 300 mm from this stove.
The stove must not be used for burning waste.
If the stove is extinguished or goes out, do not attempt to turn it back on until a mini-
mum of 3 minutes have passed.
General
English
RAIS/
attika
- User manual for Q-Tee II Gas / Q-Tee II C Gas
Summary of Contents for Q-Tee II C GAS
Page 2: ......
Page 35: ...35 4 3 5 Log 3 Log 4 Log 5 Dansk RAIS attika brugermanual til Q Tee II Gas Q Tee II C GAS ...
Page 36: ...36 6 A B Log 6 Log A Log B Dansk RAIS attika brugermanual til Q Tee II Gas Q Tee II C GAS ...
Page 75: ...75 Dansk RAIS attika brugermanual til Q Tee II Gas Q Tee II C GAS ...
Page 148: ...75 Deutsch RAIS attika Bedienungsanleitung für Q Tee II Gas Q Tee II C Gas ...
Page 181: ...35 4 3 5 English RAIS attika User manual for Q Tee II Gas Q Tee II C Gas Log 3 Log 4 Log 5 ...
Page 182: ...36 6 A B English RAIS attika User manual for Q Tee II Gas Q Tee II C Gas Log 6 Log A Log B ...
Page 195: ...49 English RAIS attika User manual for Q Tee II Gas Q Tee II C Gas ...
Page 196: ...50 English RAIS attika User manual for Q Tee II Gas Q Tee II C Gas ...
Page 221: ...75 English RAIS attika User manual for Q Tee II Gas Q Tee II C Gas ...
Page 294: ...75 Français RAIS attika Manuel d utilisateur pour Q Tee II Gas Q Tee II C Gas ...
Page 399: ...35 4 3 5 Svenska RAIS attika Bruksanvisning til Q Tee II Gas Q Tee II C Gas Log 3 Log 4 Log 5 ...
Page 400: ...36 6 A B Svenska RAIS attika Bruksanvisning til Q Tee II Gas Q Tee II C Gas Log 6 Log A Log B ...
Page 439: ...75 Svenska RAIS attika Bruksanvisning til Q Tee II Gas Q Tee II C Gas ...
Page 584: ...A A A 598 590 I E 250 D 50 149 M 76 460 410 582 291 291 149 Q Tee II Gas ...
Page 589: ...83 A A A E 250 D 50 330 179 660 479 598 590 76 460 179 M 330 Q Tee II C Gas ...