11
UK
Installation
It is important that the stove is correctly installed from both an environ-
mental and safety point of view.
The stove must only be installed by a Gas Safe Registered engineer.
When installing the stove, all local rules and regulations, including those
referring to national and European standards must be complied with.
The installation must comlpy with the Building Regulations and Gas Safe-
ty (Installation and use) Regulation.
There must be no unauthorised modifications of the stove.
Before installation begins, it should be confirmed that the information
on the data plate regarding gas type and pressure is in accordance with
the local gas supply conditions under which the stove is to be installed.
You should ensure that the gas supply can supply the required quantity
of gas and pressure as described on the data plate. It is advisable to wear
gloves when installing and servicing the stove.
Gas connection
The inlet supply pipe has an external diameter of Ø8mm. An isolation
tap must be fitted.
Ventilation
This stove has a sealed combustion chamber and is intended for a bal-
anced draught. There is therefore no need for an extra air supply.
It is recommended that sufficient fresh air is supplied to the room to
maintain a comfortable environment.
This stove may be installed in a completely airtight building or a building
with mechanical ventilation.
installation of stove
Summary of Contents for NEXO 100 Classic Gas
Page 1: ...1 POSITIV N E X O G A S GB UK ...
Page 34: ...34 ceramic Logs Log 1 Log 2 Log 3 Log 4 Log 6 Log A Log B UK Log 5 ...
Page 36: ...36 4 3 5 Log 3 Log 4 Log 5 UK ...
Page 37: ...37 6 A B Log 6 Log A Log B UK ...
Page 50: ...50 UK ...
Page 51: ...51 UK ...
Page 56: ...56 UK ...
Page 85: ...1 2 3 4 5 NEXO Gas 100 120 140 160 185 ...
Page 86: ...86 1 2 3 4 5 8 6 9 8 7 10 NEXO G Gas 100 120 140 160 185 ...
Page 87: ...87 ...