Rainbow RK-3001-TRREC-N01 Manual Download Page 8

 Moisture 

Online 

Address: 0 

Baud rate: 4800 

 

ure

 

23.5

 

%

 

3.2

 

Introduction to the main interface 

 
 
 
 
 
 
 
 
 

 

Moist

 

   

 
 
 
 
 
 
 

 

Serial 

number 

name 

Description 

time 

Display the current time (manual adjustment) 

Call the 

police 

As shown in the figure, the total alarm sound is turned on 

(the buzzer alarm can be turned off separately), when 

displayed, it means the total alarm is turned on 

USB socket 

After inserting the USB, this logo is displayed 

data record 

As shown in the figure, it indicates that the recording data 

is turned on (you can set to turn on or off the recording 

data)

When 

 

is displayed, it means that the recording 

data is closed 

buzzer 

As shown in the figure, the buzzer is normally enabled, 

and when the buzzer is disabled, it will display: 

When the alarm is off, the buzzer cannot be activated 

Electricity 

Display the current remaining power 

Access device 

type 

Type of current access device (access device can be set

 

device status 

Display the online/offline status of the current device 

address 

The address of the access device 

10 

Baud rate 

The baud rate of the connected device 

11 

Real-time 

value 

Display the actual element value of the current detection 

12 

Percentage 

The ratio of the current measurement value to the range 

of this sensor 

Summary of Contents for RK-3001-TRREC-N01

Page 1: ...Soil Sensor with Portable Handheld Display Terminal RK 3001 TRREC N01 Ver 2 0...

Page 2: ...urement method 6 Chapter 3 Function and Operation Instructions 7 3 1 Button description 7 3 2 Introduction to the main interface 8 3 3 Operating instructions 9 3 3 1 System setting description 9 3 3 2...

Page 3: ...Sensor with Portable is widely used in the detection of soil pH dry farming and water saving irrigation precision agriculture forestry geological prospecting plant cultivation water conservancy enviro...

Page 4: ...code 3001 Soil recorder housing TRREC Soil multi parameter recorder N01 RS485 Modbus RTU protocol air No Bluetooth printing BT Print with Bluetooth not yet developed 1 5 Product selection Product Siz...

Page 5: ...the push type two in two out wire at the bottom of the connector line The line sequence corresponds to the color brown brown black black yellow yellow blue blue color If multiple soil sensors are con...

Page 6: ...the sensor vertically and insert it into the soil Do not shake left and right It is recommended to measure multiple times to find the average value within a small range of a measuring point 2 4 1 Buri...

Page 7: ...e main interface to switch the display interface of different devicesShort press on the menu interface to move the cursor to the left Right direction Short press to the right on the main interface to...

Page 8: ...turn on or off the recording data When is displayed it means that the recording data is closed 5 buzzer As shown in the figure the buzzer is normally enabled and when the buzzer is disabled it will di...

Page 9: ...red when the storage is deleted Use the up and down keys to change the time the left and right keys to move the ursor to the next position the cursor finally moves to the confirmation place and lick t...

Page 10: ...so as not to cause confusion when the configuration software views the data curve 3 3 3 View historical data description In this operation you can view historical data on the device and you can also...

Page 11: ...ameter will be written to the device This function is to facilitate the modification of individual parameters when other parameters are modified by mistake Set Software version factory default can be...

Page 12: ...n the Dr Yang recorder configuration software The software will automatically read the Read Device Information and then click Read the Stored Data to import the data stored in the detector into the co...

Page 13: ...ck Device in the toolbar and click Clear Device Storage Data in the drop down menu to clear the device data After clearing the software prompts Data Clear Successful Chapter 5 Charging Function Descri...

Page 14: ...cturer for repair circuit failure Please contact the dealer or manufacturer for repair No response when the sensor is inserted circuit failure Please contact the dealer or manufacturer for repair Inac...

Reviews: