Soil  Sensor with Portable Handheld Display Terminal developed and designed by 

our company adopts the latest digital integrated circuit technology and international 
detection technology, and designs and integrates a new type of intelligent handheld 
detector.  The  recorder  uses  a  large-size  full-color  LCD  display  that  can  display  the 
readings in real time. At the same time, it uses a detection circuit designed by a digital 
chip from an international manufacturer, which can achieve very high sensitivity and 
excellent  repeatability.  And  the  soil  integrates  storage,  recording  and  analysis,  and 
can be flexibly connected to the company's soil nitrogen, phosphorus and potassium 
sensors,  soil  electrical  conductivity,  soil  temperature  and  humidity  and  other 
equipment to achieve the measurement of various soil parameters. 

The  Soil  Sensor  with  Portable  is  widely  used  in  the  detection  of  soil  pH,  dry 

farming  and  water-saving  irrigation,  precision  agriculture,  forestry,  geological 
prospecting,  plant  cultivation,  water  conservancy,  environmental  protection  and 
other fields, as well as the measurement of various particulate matter pH. 

1.2

 

Features 

 

The measurement results can be displayed directly, which is simple and convenient, 
with low measurement cost and fast measurement speed. 

 

A variety of recording methods are available. 

 

Large-size color display screen, large-capacity storage. 

 

Data export with one key is convenient and quick. 

 

The probe plug-in design ensures accurate measurement and reliable 
performance. 

1.3

 

Main parameters 

 

Power supply 

Battery powered (5000mAh lithium battery) 

Display method 

2.8 inch LCD screen 

data storage 

100W data 

Charging time 

8h 

 

working environment 

Temperature -10

-50

; Humidity<95%RH, no 

condensation 

Accessible equipment 

1-4 ModBus device combination 

letter of agreement 

Modbus-RTU protocol 

Operating Voltage 

DC 4.2V 

Standby time 

More than 8h continuous 

size 

215*100*36 mm 

weight 

500g 

Summary of Contents for RK-3001-TRREC-N01

Page 1: ...Soil Sensor with Portable Handheld Display Terminal RK 3001 TRREC N01 Ver 2 0...

Page 2: ...urement method 6 Chapter 3 Function and Operation Instructions 7 3 1 Button description 7 3 2 Introduction to the main interface 8 3 3 Operating instructions 9 3 3 1 System setting description 9 3 3 2...

Page 3: ...Sensor with Portable is widely used in the detection of soil pH dry farming and water saving irrigation precision agriculture forestry geological prospecting plant cultivation water conservancy enviro...

Page 4: ...code 3001 Soil recorder housing TRREC Soil multi parameter recorder N01 RS485 Modbus RTU protocol air No Bluetooth printing BT Print with Bluetooth not yet developed 1 5 Product selection Product Siz...

Page 5: ...the push type two in two out wire at the bottom of the connector line The line sequence corresponds to the color brown brown black black yellow yellow blue blue color If multiple soil sensors are con...

Page 6: ...the sensor vertically and insert it into the soil Do not shake left and right It is recommended to measure multiple times to find the average value within a small range of a measuring point 2 4 1 Buri...

Page 7: ...e main interface to switch the display interface of different devicesShort press on the menu interface to move the cursor to the left Right direction Short press to the right on the main interface to...

Page 8: ...turn on or off the recording data When is displayed it means that the recording data is closed 5 buzzer As shown in the figure the buzzer is normally enabled and when the buzzer is disabled it will di...

Page 9: ...red when the storage is deleted Use the up and down keys to change the time the left and right keys to move the ursor to the next position the cursor finally moves to the confirmation place and lick t...

Page 10: ...so as not to cause confusion when the configuration software views the data curve 3 3 3 View historical data description In this operation you can view historical data on the device and you can also...

Page 11: ...ameter will be written to the device This function is to facilitate the modification of individual parameters when other parameters are modified by mistake Set Software version factory default can be...

Page 12: ...n the Dr Yang recorder configuration software The software will automatically read the Read Device Information and then click Read the Stored Data to import the data stored in the detector into the co...

Page 13: ...ck Device in the toolbar and click Clear Device Storage Data in the drop down menu to clear the device data After clearing the software prompts Data Clear Successful Chapter 5 Charging Function Descri...

Page 14: ...cturer for repair circuit failure Please contact the dealer or manufacturer for repair No response when the sensor is inserted circuit failure Please contact the dealer or manufacturer for repair Inac...

Reviews: