   A menu 

 

System settings

 

 

Equipment 
management

 

Equipment increase 

and dacrease

 

  Device 

 

Information

 

 

Storage 

settings

 

Device 

 

Configuration

 

o

 

s

 

Restore Factory

 

Use the up and down arrow keys to save the selected item, move the cursor to 
the next position with the left and right arrow keys, and finally move the cursor t 
write, click the arrow right key to enter the device list, and then press the arrow 
up and down keys to select a different device Set the upper and lower alarm limit 

for it. First select the device to be set, then select the element

s alarm type, set 

the alarm value again, and move the light paste

 

Use the up and down arrow keys to change the selected item, the left and right

 

arrow keys to move the cursor to the next position, after the light, move to the 
clear division, click the right arrow key to enter the device list, and then press the 
up and down arrow keys to select a different device to it Carry out modification 
and division operations. The modified address and baud rate are only valid for 

the device, and the device address and baud rate of the external sensor will not 
be changed.

 

3.3.2

 

Equipment management instructions 

Note: When connecting multiple sensors at the same time, the sensor addresses 
should not conflict, so as not to cause confusion when the configuration software 
views the data curve. 

 

 

3.3.3

 

View historical data description 

In  this  operation,  you  can  view  historical  data  on  the  device,  and  you  can  also 

import  the  stored  data  of  the  device  to  the  computer  for  viewing.  For  specific 
operations, please refer to the instructions in Section 4.2 and 4.3. 

 

      A menu 

 

 

 

  System settings

 

 

Equipment 
management

 

 

 

Device Information

 

 

 

 Storage settings

 

 

 

Restore Factory

 

 
 

Move the cursor to the value increase/decrease box after the current index, 

and scroll the historical data through the up and down direction keys to

 

view the stored data from different times; move the cursor in the left and 
right directions to select the device name, element name, address and baud 

rate . For example, to view the humidity data of a temperature and humidity 
device, you can use the left and right arrow keys to move the cursor and click 
the filter box below the device name, then use the up and down arrow keys 
to select the "temperature and humidity" device, and then use the right 

arrow Key to move the cursor to the filter box below the element name, use 
the up and down arrow keys to select the "moisture" element, then use the 
left and right arrow keys to move the cursor to the current index, then use 
the up and down arrow keys to move the cursor to the current index The 

arrow keys scroll through historical data.

 

he up and down arrow keys to move the cursor to the current index The

 

Summary of Contents for RK-3001-TRREC-N01

Page 1: ...Soil Sensor with Portable Handheld Display Terminal RK 3001 TRREC N01 Ver 2 0...

Page 2: ...urement method 6 Chapter 3 Function and Operation Instructions 7 3 1 Button description 7 3 2 Introduction to the main interface 8 3 3 Operating instructions 9 3 3 1 System setting description 9 3 3 2...

Page 3: ...Sensor with Portable is widely used in the detection of soil pH dry farming and water saving irrigation precision agriculture forestry geological prospecting plant cultivation water conservancy enviro...

Page 4: ...code 3001 Soil recorder housing TRREC Soil multi parameter recorder N01 RS485 Modbus RTU protocol air No Bluetooth printing BT Print with Bluetooth not yet developed 1 5 Product selection Product Siz...

Page 5: ...the push type two in two out wire at the bottom of the connector line The line sequence corresponds to the color brown brown black black yellow yellow blue blue color If multiple soil sensors are con...

Page 6: ...the sensor vertically and insert it into the soil Do not shake left and right It is recommended to measure multiple times to find the average value within a small range of a measuring point 2 4 1 Buri...

Page 7: ...e main interface to switch the display interface of different devicesShort press on the menu interface to move the cursor to the left Right direction Short press to the right on the main interface to...

Page 8: ...turn on or off the recording data When is displayed it means that the recording data is closed 5 buzzer As shown in the figure the buzzer is normally enabled and when the buzzer is disabled it will di...

Page 9: ...red when the storage is deleted Use the up and down keys to change the time the left and right keys to move the ursor to the next position the cursor finally moves to the confirmation place and lick t...

Page 10: ...so as not to cause confusion when the configuration software views the data curve 3 3 3 View historical data description In this operation you can view historical data on the device and you can also...

Page 11: ...ameter will be written to the device This function is to facilitate the modification of individual parameters when other parameters are modified by mistake Set Software version factory default can be...

Page 12: ...n the Dr Yang recorder configuration software The software will automatically read the Read Device Information and then click Read the Stored Data to import the data stored in the detector into the co...

Page 13: ...ck Device in the toolbar and click Clear Device Storage Data in the drop down menu to clear the device data After clearing the software prompts Data Clear Successful Chapter 5 Charging Function Descri...

Page 14: ...cturer for repair circuit failure Please contact the dealer or manufacturer for repair No response when the sensor is inserted circuit failure Please contact the dealer or manufacturer for repair Inac...