background image

2

Installation

Tools and Supplies Needed

• 

Phillips screwdriver

• 

Wire stripper

• 

Hammer

• 

Valve wire: direct burial, color coded multi-strand (not 

included)

• 

18 gauge for runs less than 800 feet.

• 

14 gauge for runs greater than 800 feet.

• 

Watertight splice connectors (not included)

Step 1. Mount Timer

Mount the SST in an accessible location

NOTE:

 SST indoor timers are for indoor use only. SST out-

door timers can be used indoors or outdoors.

For indoor installation, choose a location within 5 feet of 

an AC power outlet and at least 15 feet away from major 

appliances or air conditioners.

Drive a screw into the wall, leaving an 1/8” gap between 

the screw-head and the wall (use the supplied wall 

anchors if necessary).

Locate the keyhole slot on back of the unit and hang it 

securely on the screw.

Remove the wiring bay cover at the bottom of the unit 

and drive a screw through the center hole as shown (use 

the supplied wall anchors if necessary).

1/8” GAP

SCREW

INDOOR 

MODEL 

SHOWN

Step 2. Connect Power

c

WARNING:

 DO NOT plug in or apply power to the timer 

until you have completed and checked all wiring connec-

tions.

Indoor Timer

Attach the transformer connector to the 24VAC POWER 

pin connection on the terminal strip.

c

WARNING:

 Do not attempt to link two or more timers 

together using a single transformer.

SST Indoor Model

TRANSFORMER

CONNECTOR

Outdoor Timer

Standard Installation

The SST outdoor version comes with a power cord and 24VAC 

transformer already connected.

Hard-wire Installation

c

WARNING:

 Disconnect or shut off the external power 

source before connecting or disconnecting wires to the 

timer.

Remove the wiring bay cover at the bottom of the unit.

Locate the wiring compartment in the lower left-hand 

corner of the unit and using a screwdriver, unscrew wiring 

compartment front cover.

CONNECT

120 VAC

RAIN & TEMP

SENSOR

SST Outdoor Model

WIRING 

COMPARTMENT

Summary of Contents for SST-900i

Page 1: ...ay 8 Seasonal Adjust 8 Error Detected 8 Manual Operation 8 Water All Zones 8 Water One Zone 8 Troubleshooting 9 Watering Issues 9 Electrical Issues 9 Installation 2 Tools and Supplies Needed 2 Step 1...

Page 2: ...unit and drive a screw through the center hole as shown use the supplied wall anchors if necessary 1 8 GAP SCREW INDOOR MODEL SHOWN Step 2 Connect Power c c WARNING DO NOT plug in or apply power to t...

Page 3: ...the field Connect a color coded wire from the direct burial cable to either wire on the valve Connect the remaining wire on each valve to a common wire which then connects to the timer NOTE Use water...

Page 4: ...n main power supply or plug the power cord into a waterproof receptacle NOTE Do not plug the timer into a socket that is con trolled by a secondary ON OFF light switch or GFI outlet Test Watering Turn...

Page 5: ...y at the water source Using a direct burial cable connect one of the wires from the master valve or pump start relay to the timer termi nal marked MSTR VALVE Using a direct burial cable connect the re...

Page 6: ...DOWN ARROWS Use UP DOWN arrows on left or right keys to set clock date run time etc AUTO RUN Set dial here to run all pro grammed settings OFF Turns off all watering RAIN DELAY Delays watering up to...

Page 7: ...blue WATERING TIMES PER DAY buttons to select the number of times per day to water WATERING DAYS WATERING TIMES PER DAY SUNDAY MONDAY TUESDAY WEDNESDAY THURSDAY FRIDAY SATURDAY ZONE OFF ONE TIME TWO...

Page 8: ...ining Current Time Seasonal Adjust Screen displays the percentage adjust ment for all zones All Durations Adjusted Season Adjust Error Detected If an error is detected the affected zone is displayed E...

Page 9: ...timer should resume normal operation Note date and time must be re entered after reset Watering cycles do not shut off Debris trapped in valve Flush the valve by temporarily opening the dump hole and...