Optional Accessories

Rain Sensor

Connect an optional Rain Sensor to the Timer

Remove the wiring bay cover at the bottom of the unit.

Remove the yellow jumper wire from the terminals 

marked 

RAIN SENSOR

 on the terminal block.

REMOVE 

JUMPER WIRE

NOTE:

 Do not remove the jumper wire unless connecting 

a rain sensor. The timer will not function if the jumper wire 

is removed and a rain sensor is not connected.

Connect the two wires from the sensor to the 

RAIN 

SENSOR

 terminals.

CONNECT 

WIRES

Master Valve Or Pump Start Relay

Connect an optional master valve or pump start 
relay

SST timers support the use of a master valve or pump start relay. 

A pump start relay connects to the timer the same way as a 

master valve, but connects differently at the water source.

Using a direct burial cable, connect one of the wires from 

the master valve (or pump start relay) to the timer termi-

nal marked 

MSTR VALVE

.

Using a direct burial cable, connect the remaining wire 

from the master valve (or pump start relay) to one of the 

timer terminals marked 

COMMON

.

MASTER 

VALVE

DIRECT 

BURIAL 

CABLE

POWER

COMMON

Additional instructions for connecting a pump start 
relay

To avoid possible pump damage, connect a short jumper 

wire from any unused zone terminal(s) to the nearest 

zone terminal in use.
Example: if a 4 zone model timer is in use with only two 

zones connected, route the terminals for zones 3 and 4 to 

the nearest active terminal (in this example, zone 2).

c

WARNING:

 Make sure that the total draw of the master 

valve (and/or pump start relay) plus the draw of the valve 

does not exceed 650mA at 24VAC, 60hz. Note that the 

timer does NOT provide main power for a pump.

ACTIVE 

TERMINAL

JUMPER 

WIRES

Summary of Contents for SST-900i

Page 1: ...ay 8 Seasonal Adjust 8 Error Detected 8 Manual Operation 8 Water All Zones 8 Water One Zone 8 Troubleshooting 9 Watering Issues 9 Electrical Issues 9 Installation 2 Tools and Supplies Needed 2 Step 1...

Page 2: ...unit and drive a screw through the center hole as shown use the supplied wall anchors if necessary 1 8 GAP SCREW INDOOR MODEL SHOWN Step 2 Connect Power c c WARNING DO NOT plug in or apply power to t...

Page 3: ...the field Connect a color coded wire from the direct burial cable to either wire on the valve Connect the remaining wire on each valve to a common wire which then connects to the timer NOTE Use water...

Page 4: ...n main power supply or plug the power cord into a waterproof receptacle NOTE Do not plug the timer into a socket that is con trolled by a secondary ON OFF light switch or GFI outlet Test Watering Turn...

Page 5: ...y at the water source Using a direct burial cable connect one of the wires from the master valve or pump start relay to the timer termi nal marked MSTR VALVE Using a direct burial cable connect the re...

Page 6: ...DOWN ARROWS Use UP DOWN arrows on left or right keys to set clock date run time etc AUTO RUN Set dial here to run all pro grammed settings OFF Turns off all watering RAIN DELAY Delays watering up to...

Page 7: ...blue WATERING TIMES PER DAY buttons to select the number of times per day to water WATERING DAYS WATERING TIMES PER DAY SUNDAY MONDAY TUESDAY WEDNESDAY THURSDAY FRIDAY SATURDAY ZONE OFF ONE TIME TWO...

Page 8: ...ining Current Time Seasonal Adjust Screen displays the percentage adjust ment for all zones All Durations Adjusted Season Adjust Error Detected If an error is detected the affected zone is displayed E...

Page 9: ...timer should resume normal operation Note date and time must be re entered after reset Watering cycles do not shut off Debris trapped in valve Flush the valve by temporarily opening the dump hole and...

Reviews: