background image

1

Introduction

Your Eagle-Signal brand B506 1/16 DIN timer is a unique instrument specifically
designed for handling repetitive cyclical operations.  This unit is highly flexible and
can be field configured to operate in a number of different fashions. Unique features
include the ability to set two separate times for On and Off operations, which can
even be in different time bases, or input a time base with a percentage value.  A
batch count function keeps track of the number of completed cycles and can stop
operation after the preset has been reached.

Inside this manual you will find complete information on the Control mode, which
deals with viewing and changing the available setpoints, and Program Mode which is
used to configure the basic operation of the timer, as well as set a variety of other
useful features.

Also found in this manual are detailed timing diagrams and descriptions of the
available operating functions to aid you in determining how to properly configure the
unit to solve your application.
Additionally included are key product
specifications, warranty procedures and
ordering information should you require
additional units or accessories.

Should you require any additional
assistance with the installation and
operation of this product, please call our
toll free application support line at 1-800-
234-8731.

• Repeat Cycle functionality with completely

independent settings for On and Off times

• Batch Count function can trigger an

output and stop the cycle

• Settings can be input as absolute time

values or as a time base and percentage

• Simple button per digit interface

• Timing resolution down to 1 ms

• Programmable security levels prevent

unauthorized setpoint or program changes

• Timed or latched batch output

• Programmable to begin with an On or an

Off operation

• IEC IP65 rated front panel

• Highly visible 8 mm dual line LED display

with 8 annunciator lights

Features

Technical Manual
702120-0001

B506
Repeat Cycle
LED Timer

Index

Overview

Panel Mounting

page 2

Wiring Connections

page 2

Operation

Front Panel

page 3

Control Mode

page 3

Configuration

Program Mode

page 4 - 6

Timing Diagrams

page 7

General

Specifications

page 8

Ordering Information

page 8

Warranty

page 8

Eagle Signal 

brand

Summary of Contents for B506

Page 1: ...lication Additionally included are key product specifications warranty procedures and ordering information should you require additional units or accessories Should you require any additional assistan...

Page 2: ...until there is a snug fit against the panel Do not overtighten 48mm 8mm 66mm 81mm B506 7051 2 1 11 2 3 4 5 6 7 8 9 10 AC Power AC Power Warning Do Not connect a coil in parallel with the start signal...

Page 3: ...currently displayed parameter Edit Key In Control Mode Displays the settable value used to trigger the timed output s and the batch count if configured In Program Mode Displays the current selection...

Page 4: ...s are Stop StoP The timing cycle will halt after the number of cycles set for the Batch Count is completed To activate another cycle it is necessary to reset the unit and provide a start signal Contin...

Page 5: ...I G U R A T I O N 1 S t O n t r n 1 Time Range 1 Sets the unit of measure for the time values that will be used for Preset 1 Choices are Seconds Minutes Hours Minutes Seconds Hours Minutes Decimal Pos...

Page 6: ...the E and P keys If inactive OFF the timing operation can only be reset through the remote input P P P r S t O n F r S t O n Security Level 4 different levels of security are available 0 Full Access...

Page 7: ...g edge of start signal or after completion of P1 based on programming On completion of P1 or Reset On reaching the Batch Count Preset Value or Reset Output 2 When the Batch Count Value equals the Batc...

Page 8: ...rized repairs to its components even though defective The life of the products of the Company depends to a large extent upon the type of usage thereof and THE COMPANY MAKES NO WARRANTY AS TO FITNESS O...

Reviews: