58
ESP-LXME Controller
Connect Flow Sensor
A
Install the flow sensor in the field according to the manufacturer’s
instructions, and run the flow sensor wire to the ESP-LXME
controller.
B
Route the flow sensor wire through the knockout on the bottom
of the controller.
C
Connect the flow sensor wire to the Flow + and Flow - inputs. When
finished, tug gently on the wires to make sure the connections are
tight.
b
b
NOTE:
For Rain Bird FS-Series flow sensors, connect the red
sensor wire to the red (+) terminal and the black sensor wire to
the grey (-) terminal.
2
3
1
b
b
NOTE:
The blue light on the FSM-LXME Flow Smart Module will
flash as flow is measured by the flow sensor.
Module Programming
Setup Flow Sensor
b
g
Turn the controller dial to Module Programming.
A
The Smart Module PGM screen appears with Flow Smart Module
selected; press Next.
B
The Flow Smart Module PGM screen appears with Flow Sensor
Setup selected; press Next.
1
2
b
b
NOTE:
If a FSM-LXME Flow Smart Module is not installed, the
screens displayed on pages 58 through 72 will not be displayed.