background image

4

© Copyright 2021. All rights reserved.

PUMP PREPARATION FOR WELL AND SURFACE WATER

  CAUTION:  

Dry-fit entire assembly to 

ensure proper fit before gluing or taping parts.

  CAUTION:  

Follow all proper gluing 

procedures as specified by the glue 

manufacturer. Always glue in a vertical direction 

whenever possible to prevent glue from 

dripping inside pipe or fittings

  CAUTION:  

Use thread tape and a thread 

paste compound on all male threads except for 

the unions. Tighten securely with a wrench and 

add another 1/4 turn to ensure proper seal.
1.  Thread 1-1/2 in. MPT x 1-1/2 in. slip adaptor 

into the outlet port located at the top of the 

pump.

2.  Glue a 6 in. piece of 1-1/2 in. pipe into the 

adaptor.

3.  Glue a 1-1/2 in. tee to the pipe.
4.  Glue a 1-1/2 in. slip x 1-1/4 in. adaptor to 

the top opening of the 1-1/2 in. tee.

5.  Thread in a 1-1/4 in. priming plug or optional 

priming plug with pressure gauge. 

NOTE: Hand tighten only, as this will be 

removed for priming.
6.  Glue another 6 in. section of 1-1/2 in. pipe 

into the opening in the 1-1/2 in. tee.

7.  Glue the male thread side of a 1-1/2 in. 

union to the pipe.

8.  Thread 2 in. MPT x 2 in. slip adaptor into 

the inlet port located on the front of the 

pump body.

9.  Glue an 8 in. section of 2 in. pipe into the 2 

in. adaptor.

10. Glue one side of a 2 in. union to the pipe.

IL1252

IL1253

Fig 2

Fig 1

IL1254

 IL1255 

Fig 4

Fig 3

Priming Plug 

with Pressure

Gauge

1-1/4 in.

Priming

Plug

Fig 6

Fig 5

Fig 8

Fig 7

Fig 10

Fig 9

Summary of Contents for BPUMP1-5HP

Page 1: ...WARNING ELECTRICAL SHOCK ALERT Follow all local electrical and safety codes as well as the National Electrical Code NEC and the Occupational Safety and Health Act OSHA ELECTRICAL SHOCK ALERT Replace...

Page 2: ...not included 1 Priming Plug with Pressure Gauge Used instead of a priming plug alone Helps determine if the pump is primed indicates if the pump is operating properly and what kind of pressure is in...

Page 3: ...e water as long as the pump is within 25 vertical feet of the water source Horizontal Distance The horizontal distance is the horizontal measurement between the pump inlet and the water source This di...

Page 4: ...op of the pump 2 Glue a 6 in piece of 1 1 2 in pipe into the adaptor 3 Glue a 1 1 2 in tee to the pipe 4 Glue a 1 1 2 in slip x 1 1 4 in adaptor to the top opening of the 1 1 2 in tee 5 Thread in a 1...

Page 5: ...n in the well 14 Glue a 90 elbow when the inlet pipe is in line with the inlet port of the pump For Surface Water Installations For surface water installations follow steps 11 and 12 above and then 15...

Page 6: ...o the female portion of the 1 1 2 in union 5 Glue 1 1 2 in ball valve to the other end of the 6 in piece of pipe 6 Connect the 1 1 2 in outlet pipe to the sprinkler system by gluing in additional sect...

Page 7: ...aces or chemicals ELECTRICAL SHOCK ALERT The pump must be properly grounded using the proper wire cable with ground ELECTRICAL SHOCK ALERT Always disconnect pump from electricity before performing any...

Page 8: ...Connect green ground wire to green grounding screw Re install rear motor cover to pump To change from 230 V to 115 V 6 The motor of pump is dual voltage and can run on either 115 volts or 230 volts In...

Page 9: ...and continue adding water to pump cavity until water comes out of the open outlet pipe at the open union 5 Wait 10 minutes to see if water level drops below the pipe tee If level drops check foot val...

Page 10: ...wise to remove from shaft 4 Use a screwdriver to remove the rotary seal B Pry the ceramic seal and rubber gasket from the recess of the mounting bracket Fig 1 CAUTION Be careful not to damage the moto...

Page 11: ...ak in inlet line 1 Repair or replace inlet line Use thread tape and pipe sealing compound 2 Vertical lift too high 2 Reduce vertical lift install foot valve and prime 3 Insufficient inlet pressure or...

Page 12: ...placement Part Kits 1 1 1 1 1 1 Standard hardware item NOTE Motor assembly not available as a replacement part PRODUCT SPECIFICATIONS Model HP Suction Lift Ft Discharge Pressure PSI Shut Off Pressure...