WIRE SIZE CHART

Distance From 

Motor To Fuse 

Box, Meter or 

Electrical Outlet

Minimum Copper Wire Size Chart 

(Gauge)

Single Phase Motors

1 HP

1-1/2 HP

115  

Volt

230  

Volt

115  

Volt

230  

Volt

0-50 Ft.

50-100 Ft.

100-150 Ft.
150-200 Ft.
200-300 Ft.

Fuse Size (Amps)

12
10

8

*
*

30

14
14
12
12
10
15

12
10

8

*
*

30

14
14
12
12
10
20

(*) 

Not economical to run in 115V, use 230V

PUMP ELECTRICAL INSTRUCTIONS

WARNING

ELECTRICAL SHOCK ALERT.

Under-size wiring can cause motor failure and 

even fire. Use proper wire size specified in the 

wire size chart.

ELECTRICAL SHOCK ALERT.

Replace damaged or worn wiring cord immediately.

ELECTRICAL SHOCK ALERT.

Do not kink power cable and never allow the cable 

to come in contact with oil, grease, hot surfaces, or 

chemicals.

ELECTRICAL SHOCK ALERT.

The pump must be properly grounded using 

the proper wire cable with ground.

ELECTRICAL SHOCK ALERT.

Always disconnect pump from electricity 

before performing any work on the motor.

WARNING

ELECTRICAL SHOCK MAY OCCUR

All wiring should be performed by a qualified 

electrician in accordance with the National Electric 

Code and local electric codes.

ELECTRICAL SHOCK MAY OCCUR

Connect the pump to a separate electrical circuit 

with a dedicated circuit breaker. Reference the wire 

size chart below for proper fuse size.

ELECTRICAL SHOCK MAY OCCUR

Protect the power cable from coming in contact with 

sharp objects.

PRODUCT DAMAGE MAY RESULT

Make certain that the power source matches 

the pump requirements. This pump has a dual 

voltage motor and can run on 115 V or 230 V. 

This pump is wired from the factory to run on 

230 volts; refer to Electrical Instructions if you 

want to change the pump to run on 115 volts.

Summary of Contents for BPUMP1-5HP

Page 1: ...WARNING ELECTRICAL SHOCK ALERT Follow all local electrical and safety codes as well as the National Electrical Code NEC and the Occupational Safety and Health Act OSHA ELECTRICAL SHOCK ALERT Replace...

Page 2: ...not included 1 Priming Plug with Pressure Gauge Used instead of a priming plug alone Helps determine if the pump is primed indicates if the pump is operating properly and what kind of pressure is in...

Page 3: ...e water as long as the pump is within 25 vertical feet of the water source Horizontal Distance The horizontal distance is the horizontal measurement between the pump inlet and the water source This di...

Page 4: ...op of the pump 2 Glue a 6 in piece of 1 1 2 in pipe into the adaptor 3 Glue a 1 1 2 in tee to the pipe 4 Glue a 1 1 2 in slip x 1 1 4 in adaptor to the top opening of the 1 1 2 in tee 5 Thread in a 1...

Page 5: ...n in the well 14 Glue a 90 elbow when the inlet pipe is in line with the inlet port of the pump For Surface Water Installations For surface water installations follow steps 11 and 12 above and then 15...

Page 6: ...o the female portion of the 1 1 2 in union 5 Glue 1 1 2 in ball valve to the other end of the 6 in piece of pipe 6 Connect the 1 1 2 in outlet pipe to the sprinkler system by gluing in additional sect...

Page 7: ...aces or chemicals ELECTRICAL SHOCK ALERT The pump must be properly grounded using the proper wire cable with ground ELECTRICAL SHOCK ALERT Always disconnect pump from electricity before performing any...

Page 8: ...Connect green ground wire to green grounding screw Re install rear motor cover to pump To change from 230 V to 115 V 6 The motor of pump is dual voltage and can run on either 115 volts or 230 volts In...

Page 9: ...and continue adding water to pump cavity until water comes out of the open outlet pipe at the open union 5 Wait 10 minutes to see if water level drops below the pipe tee If level drops check foot val...

Page 10: ...wise to remove from shaft 4 Use a screwdriver to remove the rotary seal B Pry the ceramic seal and rubber gasket from the recess of the mounting bracket Fig 1 CAUTION Be careful not to damage the moto...

Page 11: ...ak in inlet line 1 Repair or replace inlet line Use thread tape and pipe sealing compound 2 Vertical lift too high 2 Reduce vertical lift install foot valve and prime 3 Insufficient inlet pressure or...

Page 12: ...placement Part Kits 1 1 1 1 1 1 Standard hardware item NOTE Motor assembly not available as a replacement part PRODUCT SPECIFICATIONS Model HP Suction Lift Ft Discharge Pressure PSI Shut Off Pressure...

Reviews: