SR2611-2S-S2R+ (6G)
4
5. Setting RAID Mode
Please select the RAID mode with the jumper located at the back panel. The original default is RAID
1, still there are three pins at the back panel for RAID mode selection: RAID 0 mode by setting the
jumper on the bottom of the two pins. RAID 1 mode by setting the jumper on the top of the two pins.
1. RAID 1 Mode (default)
1). Insert two brand new hard drives into .
2). As RAID 1 is composed of two hard drives, it can be referred to as disk mirroring, each data will
simultaneously be written in two hard drives and the data in two hard drives are exactly the
ame. Whenever one of the hard drives is failed, the system is still able to work normally. Once
the failed hard drive is replaced by a new one, will start auto-rebuilding.
The computing method of RAID 1 hard disk capacity:
[total capacity] = [minimum capacity of hard drive]
Ex:
2 × 500GB HDD=500GB
1 × 500GB HDD+1× 200GB HDD=200GB
RAID 0 Mode RAID 1 Mode
Internal Case
※
Note :
1.
RS232 Port and RS232 Cable: Provides hardware status monitoring to industrial control system or IPC via RS232.
2. We do not recommend users to disassemble the device without proper instructions and authorization. The manufacture warranty
will not cover the damages caused by unauthorized disassembling.
3. To prevent the device from malfunction, please make sure the device is connected with a direct and dedicated power connection of
a stable power input.