5.4
Connection of Disk Array Unit to Business Server
Connect an FC cable between an RAID Storage host connection port (HP connector) and the
business server.
Host connection port
(HP connector)
Host connection port
(HP connector)
Host connection port
(HP connector)
CONT1 CONT0
Figure 5.4.1 Rear View of Disk Array Unit
Host connection port
(HP connector)
The figure below shows a sample recommended connection (a path redundant configuration in
combination with PathManager).
The sample recommendation requires two host bus adapters to be installed in the host.
Two LC-LC cables are required to connect the disk array unit and host bus adapters.
A one-controller unit requires a single host bus adapter and a single cable.
Configuration sample:
Business server
Host bus
adapter
Host bus
adapter
FC cable (LC-LC cable)
* The dust-proof cover put on the host connection port of the controller is required when the
controller is moved. Keep it in a safe place.
-
42
-