![background image](http://html1.mh-extra.com/html/radwin/rw-5200-0250/rw-5200-0250_user-manual_3381460034.webp)
RADWIN 5000 HPMP User Manual
Release 3.1.00
3-10
Installing a Sector using PoE Devices
Chapter 3
2. Connect the lightning protection device to the ODU (see
Chapter 18
).
3. Attach the ODU-PoE cable to the ODU RJ-45 connector (see
Appendix B
for the
connector pinout)
4. Screw in the cable glands to ensure hermetic sealing of the ODU.
5. Secure the cables to the pole, mast or brackets using UV-rated cable ties.
Installing a Sector using PoE Devices
A typical PoE device is a very simple unit having a power input connector and two Ethernet
ports. It is AC powered, and has a power LED.
To prepare a sector using PoE devices:
1. To connect the ODU to the PoE device, route the cable from the ODU to the PoE
device, secure the cable along its path and connect the cable to the LAN-OUT RJ-45
connector on the PoE device.
2. Connect it to AC power.
3. Repeat steps 1 to 2 for all ODUs in the sector.
Connecting User Equipment
To connect user equipment to a PoE device:
• Connect a user switch, router or any other compatible device to the PoE device RJ-45
port designated LAN-IN. Refer to
Appendix B
for connector pinouts.
Aligning HSUs to a HBS
You perform HSU antenna alignment to a HBS using the HSU ODU’s audible tone.
To align a HSU to its HBS:
1. Ensure that the sector antenna of the HBS is aligned precisely to the sector it is
intended to cover. Use a compass and topographical maps to do this.
2. For both the HBS and HSUs: Using a coax cable with N-Type connectors, connect the
vertical polarization connector of the antenna to the ANT 1 connector of the ODU.
Then, using a second coax cable with N-Type connectors, connect the horizontal
polarization connector of the antenna to the ANT 2 connector of the ODU.
Note
There is no particular reason to use ANT 1 and ANT 2 in that order: They
just have to be the same for each ODU in the sector. Further, adopting a
convention like “ANT 1 is always vertical” avoids mistakes across a large
sector.
3. Ensure that power is connected to the site PoEs across the sector.
4. Provided that an HSU detects the signal from the HBS, the ODU starts beeping 20
seconds after power up, and continues beeping until the HSU is aligned to the HBS,
and the alignment is complete.