RADWIN
2000
C
Plus
User
Manual
Release
3.5.70
C
‐
41
MIB
Traps
Chapter
C
externalAlarmInPort3Alarm
112
major
The
trap
is
sent
every
time
an
alarm
occurs
in
the
External
Alarm
Input
of
port
#3.
Contains
a
single
parameter
which
is
its
description:
1
‐
Description:
External
Alarm
3
‐
<User
Text>
‐
Alarm.
externalAlarmInPort4Alarm
113
major
The
trap
is
sent
every
time
an
alarm
occurs
in
the
External
Alarm
Input
of
port
#4.
Contains
a
single
parameter
which
is
its
description:
1
‐
Description:
External
Alarm
4
‐
<User
Text>
‐
Alarm.
swVersionsMismatchFullCompatibilityAlarm
114
warning
The
trap
is
sent
if
SW
versions
mismatch
with
full
link
functionality.
Contains
a
single
parameter
which
is
its
description:
1
‐
Description:
Software
versions
mismatch
‐
full
link
functionality
swVersionsMismatchRestrictedCompatibilityAlarm
115
minor
The
trap
is
sent
if
SW
versions
mismatch
with
restricted
link
functionality.
Contains
a
single
parameter
which
is
its
description:
1
‐
Description:
Software
versions
mismatch
‐
restricted
link
functionality
swVersionsMismatchSoftwareUpgradeRequired
116
major
The
trap
is
sent
if
SW
versions
mismatch
and
SW
upgrade
is
required.
Contains
a
single
parameter
which
is
its
description:
1
‐
Description:
Software
versions
mismatch
‐
Software
upgrade
required
swVersionsIncompatible
117
critical
The
trap
is
sent
if
SW
versions
are
incompatible.
Contains
a
single
parameter
which
is
its
description:
1
‐
Description:
SW
Versions
incompatible
hssMultipleSourcesDetectedAlarm
118
major
Indicates
that
multiple
sync
pulse
sources
were
detected.
Contains
a
single
parameter
which
is
its
description:
1
‐
Description:
HSS
multiple
sync
sources
were
detected.
hssSyncToProperSourceStoppedAlarm
119
major
Indicates
that
synchronization
to
a
proper
sync
pulse
source
was
stopped.
Contains
a
single
parameter
which
is
its
description:
1
‐
Description:
HSS
sync
pulse
‐
Down.
The
reason
is:
%s.
%s
‐
Is
the
reason
for
the
sync
down.
hssSyncPulseDetectedAlarm
120
major
Indicates
that
HSS
additional
sync
pulse
was
detected.
Contains
a
single
parameter
which
is
its
description:
1
‐
Description:
HSS
additional
sync
pulse
was
detected.
tdmBackupAlarm
121
major
Indicates
that
the
TDM
backup
link
was
activated.
Contains
a
single
parameter
which
is
its
description:
1
‐
Description:
TDM
backup
alarm
‐
backup
link
was
activated.
linkLockUnauthorizedRemoteODU
122
major
Indicates
that
the
remote
ODU
is
unauthorized.
Contains
a
single
parameter
which
is
its
description:
1
‐
Description:
Unauthorized
remote
ODU
connection
rejected.
linkLockUnauthorizedODU
123
major
Indicates
that
the
ODU
is
unauthorized.
Contains
a
single
parameter
which
is
its
description:
1
‐
Description:
Unauthorized
ODU
connection
rejected.
hotStandbyAlarm
124
major
Indicates
that
the
hot
standby
secondary
link
was
activated.
Contains
a
single
parameter
which
is
its
description:
1
‐
Description:
Secondary
Link
Is
Active.
sfpInsertion
126
normal
Indicates
that
a
device
was
inserted
to
SFP
Port
sfpPort1DisconnectedAlarm
127
major
Indicates
the
SFP
port
1
status
changed
to
disconnected.Contains
a
single
parameter
which
is
its
description:
1
‐
Description:
SFP
port
1
status
changed
to
disconnected.
ringRplStateActiveAlarm
128
major
RPL
state
changed
to
Active.
desiredRatioCanNotBeAppliedAlarm
129
normal
Indicates
Desired
UL/DL
RAtio
Can
Not
Be
Applied.
Table
C
‐
3:
MIB
Traps
(Sheet
4
of
8)
Name
ID
Severity
Description
Summary of Contents for 2000 C PLUS
Page 1: ...USER MANUAL RADWIN 2000 C PLUS POINT TO POINT BROADBAND WIRELESS Release 3 5 70...
Page 17: ...Part 1 Basic Installation Release 3 5 70...
Page 139: ...Part 2 Site Synchronization Release 3 5 70...
Page 166: ...Part 3 Advanced Installation Topics Release 3 5 70...
Page 167: ...RADWIN 2000 C Plus User Manual Release 3 5 70 12 1 Chapter 12 Reserved...
Page 188: ...RADWIN 2000 C Plus User Manual Release 3 5 70 17 1 Chapter 17 Reserved...
Page 189: ...Part 4 Field Installation Topics Release 3 5 70...
Page 219: ...Part 5 Product Reference Release 3 5 70...
Page 296: ......