RADWIN
2000
C
Plus
User
Manual
Release
3.5.70
C
‐
24
Private
MIB
Parameters
Chapter
C
winlink1000OduAgnCurrAlarmTable
N/A This
table
includes
the
currently
active
alarms.
When
a
RAISED
trap
is
sent
an
alarm
entry
is
added
to
the
table.
When
a
CLEAR
trap
is
sent
the
entry
is
removed.
winlink1000OduAgnCurrAlarmEntry
N/A Entry
containing
the
details
of
a
currently
RAISED
trap.
INDEX
{
winlink1000OduAgnCurrAlarmCounter
}
winlink1000OduAgnCurrAlarmCoun
ter
RO
A
running
counter
of
active
alarms.
The
counter
is
incremented
for
every
new
RAISED
trap.
It
is
cleared
after
a
device
reset.
winlink1000OduAgnCurrAlarmSeve
rity
RO
Current
Alarm
severity.
winlink1000OduAgnCurrAlarmId
RO
Unique
Alarm
Identifier
(combines
alarm
type
and
interface).
The
same
AlarmId
is
used
for
RAISED
and
CLEARED
alarms.
winlink1000OduAgnCurrAlarmIfInd
ex
RO
Interface
Index
where
the
alarm
occurred.
Alarms
that
are
not
associated
with
a
specific
interface
will
have
the
following
value:
65535.
winlink1000OduAgnCurrAlarmUnit
RO
Unit
associated
with
the
alarm.
winlink1000OduAgnCurrAlarmTrapI
D
RO
ID
of
the
raised
trap
that
was
sent
when
this
alarm
was
raised.
winlink1000OduAgnCurrAlarmTime
T
RO
Timestamp
of
this
alarm.
This
number
is
in
seconds
from
Midnight
January
1st
1970.
winlink1000OduAgnCurrAlarmText
RO
Alarm
display
text
(same
as
the
text
in
the
sent
trap).
winlink1000OduAgnLastEventsNum
ber
1.3.6.1.4.1.4458.1000.1.7.4.
1
Integer
RO
This
counter
indicates
the
size
of
the
winlink1000OduAgnLastEventsTable
winlink1000OduAgnLastEventsTable
N/A This
table
includes
the
last
events.
When
a
trap
is
sent
an
event
entry
is
added
to
the
table.
winlink1000OduAgnLastEventsEntr
y
N/A Entry
containing
the
details
of
last
traps.
INDEX
{
winlink1000OduAgnLastEventsIndex
}
winlink1000OduAgnLastEventsInde
x
1.3.6.1.4.1.4458.1000.1.7.4.
2.1.1
Integer
RO
The
index
of
the
table
winlink1000OduAgnLastEventsSeve
rity
1.3.6.1.4.1.4458.1000.1.7.4.
2.1.2
Integer
RO
Current
Trap
severity.
winlink1000OduAgnLastEventsIfInd
ex
1.3.6.1.4.1.4458.1000.1.7.4.
2.1.3
Integer
RO
Interface
Index
where
the
event
occurred.
Traps
that
are
not
associated
with
a
specific
interface
will
have
the
following
value:
65535.
winlink1000OduAgnLastEventsTime
T
1.3.6.1.4.1.4458.1000.1.7.4.
2.1.4
Integer
RO
Timestamp
of
this
trap.
This
number
is
in
seconds
from
Midnight
January
1st
1970.
winlink1000OduAgnLastEventsText
1.3.6.1.4.1.4458.1000.1.7.4.
2.1.5
DisplayString
RO
Trap
display
text
(same
as
the
text
in
the
sent
trap).
winlink1000IduAdmProductType
RO
IDU
configuration
description.
winlink1000IduAdmHwRev
RO
IDU
Hardware
Revision.
winlink1000IduAdmSwRev
RO
IDU
Software
Revision.
winlink1000OduAdmNumOfExterna
lAlarmIn
RO
Indicates
the
number
of
currently
available
External
Alarm
Inputs.
winlink1000OduAdmExternAlarmIn
Table
N/A This
is
the
External
Alarm
Inputs
table.
winlink1000OduAdmExternAlarmIn
Entry
N/A Entry
containing
the
elements
of
a
single
External
Alarm
Input.
INDEX
{
winlink1000OduAdmExternAlarmInIndex}
winlink1000OduAdmExternAlarmIn
Index
RO
This
value
indicates
the
index
of
the
External
Alarm
Input
entry.
Table
C
‐
2:
Private
MIB
Parameters
(Sheet
19
of
32)
Name
OID
Type
A
cce
ss
Description
Summary of Contents for 2000 C PLUS
Page 1: ...USER MANUAL RADWIN 2000 C PLUS POINT TO POINT BROADBAND WIRELESS Release 3 5 70...
Page 17: ...Part 1 Basic Installation Release 3 5 70...
Page 139: ...Part 2 Site Synchronization Release 3 5 70...
Page 166: ...Part 3 Advanced Installation Topics Release 3 5 70...
Page 167: ...RADWIN 2000 C Plus User Manual Release 3 5 70 12 1 Chapter 12 Reserved...
Page 188: ...RADWIN 2000 C Plus User Manual Release 3 5 70 17 1 Chapter 17 Reserved...
Page 189: ...Part 4 Field Installation Topics Release 3 5 70...
Page 219: ...Part 5 Product Reference Release 3 5 70...
Page 296: ......