34
Intr
oduction
Configur
ation
Ins
tallation
Radionode365
Tapacul
o Lit
e
Cus
tomer Servic
e
Inf
ormation
Telnet
Commands
HT
TP R
adionode
Pr
ot
oc
ol V1
Modbus
Regis
tration
About this Manual
HTTP Radionode Protocol V2
Radionode users can build their own servers that receive
measurement data from radionode devices, such as the RN400
Series data loggers or RN17xWC Series data transmitters, instead
of the Radionode365. This chapter describes the POST-method
HTTP request format used by radionode devices for customer server
developers.
Customer servers must proceed the following two requests:
●
The radionode device requests transmission of device
information from the server at the start of operation and every
six hours thereafter. This request is called check-in.
●
The device requests transmission of measurement data from the
server at the set time. This request is called data-in.
Check-in
Check-in requests are in the following format:
POST / HTTP/1.1
POST / HTTP/1.1
Host: 192.168.10.1/checkin
Host: 192.168.10.1/checkin
Content-Type: application/x-www-form-urlencoded
Content-Type: application/x-www-form-urlencoded
Content-Length: 589
Content-Length: 589
mac=0000xxxx0000&
mac=0000xxxx0000&
ver=20201031&
ver=20201031&
model=RN171WC&
model=RN171WC&
ip=192.168.100.11&
ip=192.168.100.11&
splrate=60&
splrate=60&
interval=300&
interval=300&
tags=xxx|xxx|xxx
tags=xxx|xxx|xxx
HT
TP R
adionode
Pr
ot
oc
ol V2