D7212 Installation and Troubleshooting Quick Reference

Page  7

74-06914-000-A 8/93

© 1993 Radionics

Problems Programming the Panel

Before attempting to program the D7212, you should be familiar with the basic operation of the
D5200 programmer. See the 

D5200 Operation Manual  (74-06176-000). If you still experience

problems, check for the symptoms below.

Symptom

Diagnosis

Remedy

The programmer
displays  
PLUG IN 7212 when
you press SEND or
RECV.

The programmer is not
correctly connected to
the D7212.

1.

Verify that the data/power cord is plugged
into the COMMUNICATOR port on the
D5200.   

2.

Verify that the data/power cord is plugged
securely into the D5200 programmer.

3.

Check each conductor in the data/power
cord for continuity.   

AC induction through
the on-board point
sensor loops, the
DATA BUS, or the
ZONEX BUS.

1.

Verify a proper earth ground at terminal 10.

2

Disconnect on-board point sensor loops,
the DATA BUS (terminals 30, 31), and the
ZONEX BUS (terminals 27,28).

After plugging in the
programmer, the
panel transmits SDI
trouble reports for
supervised SDI
devices (command
centers, printer
interface modules,
etc.). All SDI devices
stop operating.

You haven’t entered
the D7212 handler
within 30 seconds of
plugging in the
programmer.

Enter the D7212 handler within 30 seconds of
plugging in the programmer.   

Once the SDI reports are generated,  entering
the handler or disconnecting the programmer
returns the SDI devices to normal operation.

Summary of Contents for D7212

Page 1: ...rminal Description 12 Introduction This reference contains the very basic information a trained installer needs to install and troubleshoot a D7212 system See the D7212 Operation and Installation Manu...

Page 2: ...are AREA IS ON AREA IS OFF Follow the procedure below to toggle between custom and default idle text 1 Ensure the command center is at idle text 2 Press COMMAND 5 7 3 The display will change to defau...

Page 3: ...connected to same ZONEX as a D8125 Connect only one OctoPOPIT with switch 12 ON to ZONEX If ZONEX is connected to a D8125 turn switch 12 OFF for all OctoPOPITs connected to that terminal POPIT is not...

Page 4: ...Faulted points do not generate alarms or troubles as programmed Command 47 pressed at the time the alarm or trouble was generated The D7212 ignores input from all points in the same area programmed fo...

Page 5: ...FOR TYPICAL BURGLAR ALARM APPLICATIONS SUITABLE FOR VALVE TAMPER AND OTHER TYPES OF EXTINGUISHING SYSTEM SUPERVISION TYPICAL INITIATING DEVICES ARE DOOR CONTACTS NO NC FLOOR MATS MOTION SENSORS GLASS...

Page 6: ...keys is stuck under the faceplate Press each of the keys on the command center to be certain none of them is stuck Data connections yellow and green wires on one or more command centers are reversed...

Page 7: ...is plugged securely into the D5200 programmer 3 Check each conductor in the data power cord for continuity AC induction through the on board point sensor loops the DATA BUS or the ZONEX BUS 1 Verify...

Page 8: ...s 1 and 8 5 Verify that all telephones are on hook Leaving a telephone on hold after the other party hangs up creates an off hook condition Verify that no phones are on hold If completing the steps ab...

Page 9: ...y signal for all ten attempts to reach the receiver Calls are not reaching the receiver 1 Verify that correct prefixes and phone numbers for the receiver have been programmed into the D7212 2 Verify t...

Page 10: ...7 8 SWITCHED AUX POWER Supplies up to 1 4 Amps at 10 0 VDC to 13 9 VDC Use terminal 9 for common Programmed as Relay C Continuous output interrupted by CMD 47 or alarm verification Shares circuit bre...

Reviews: