When the DSC mode is selected as head track, the DSC port of RC4GS V3 outputs in channel 5 and channel
6 by default. Then connect the roll servo and pitch servo used to control the pan-tilt to the pins of R6FG
receiver in channel 5 and channel 6, and then swing the FPV goggles up and down or left and right, and the
servos of the corresponding channel will swing accordingly.
Note:
1. When head track function is used on RC4GS V3, only channel 5 is available.
2. If you want to realize the head track function, please make sure the FPV goggles used support head track
function.
Please refer to the video for The connection method of RC4GS V3 to FPV goggles:
https://www.youtube.com/watch?v=COYvtdWBTdY
2.24 Timer Setting “TIMER”
TIMER function is mainly used for game timing, and for daily training.
Enter the setting interface:
Long press "Exit" and "Enter" button simultaneously for one second to enter the
function menu of RC4GS V3. Press "Inc(+)" button at the bottom of the screen to move the cursor to "24.
TIMER", and then press " Enter” button to enter the function setting interface.
Mode: Timer mode, you can choose "UP TIMER" or "DOWN TIMER".
UP TIMER: After triggering the timing function, the timing number will count
upwards.
DOWN TIMER: After triggering the timing function, the timing numbers will
count down.
Alarm: The timer starts. When it reaches the set time, the transmitter starts
to alarm. In the countdown 20S, it starts to alarm every 1S. In the
countdown 10S, it starts to alarm twice every 1S. When the alarm time is
reached, the transmitter will give a alarm. If the switch is not toggled now,
the timing will continue. The default alarm time is 8 minutes. The alarm time
can be set according to actual needs
START: Select a switch or button used to trigger the timing function. You can choose SWA, SWD, TH (throttle
trigger), and the lock mode of the two switch buttons.
NULL means that the timing function is not enabled. If the switch is set to
SWA, SWD or their lock modes, you can select UP (up), or DOWN (down)
for the position of the switch to trigger the timing function.
If the start switch is TH (throttle trigger), you can set the throttle rate to
0%-100%, and the timing function will be triggered when the throttle trigger
is pushed to the set rate.
STOP: It is used to stop the timing function. The setting method is the
same as the above "START" setting. When the number of laps set is
greater than 1, the number of laps will automatically increase by 1 lap each
time it stops.
RESET: By toggling the switch set here, all the previously generated timing values will be cleared.Alarm
values and laps are retained. The switch setting method is the same as the above "START" setting.