PG
6
or remotely using a Z-Wave® USNAP module. See the thermostat instruction
book for how to enter simple mode
Advanced Z-Wave® Information
The RTZW-02 supports compliant mapping of the Z-Wave® BASIC_
COMMAND_CLASS to the CT thermostat “Energy Saving” and “Comfort
Mode” as follows:
Basic Set (Value = 0x00) = Set Energy Saving Mode
Basic Set (Value = 0x01-0x63 & 0xFF) = Set Comfort Mode
Energy Savings applies a 4
o
F setback to the existing set point temperature to
comply with EPA recommendations for energy savings.
Association group:
This device support one association group, and up to two nodes in that group. If at
least one node is added to association group one (1), the thermostat will send the
following association reports when the respective state has changed:
• Thermostat Mode Report
• Thermostat Operating State Report
• Fan Mode Report
• Fan State Report
• Setpoint Report (for all supported setpoints)
• Sensor Multilevel Report (if enabled by Configuration Command Class)