9. Thermostat Recovery Mode (8-bit)
The Thermostat Recovery Mode can be either fast (0x01) or economy (0x02).
10. Thermostat Reporting Filter(16-bit):
Set Command Definition
7
6
5
4
3
2
1
0
Command Class = COMMAND_CLASS_CONFIGURATION
Command = CONFIGURATION_SET
Parameter = 0x0A
Default
RESERVED S
ize = 0x04
Precision (0x00) S
cale B
ound Size (0x01)
Temperature Filter Lower Bound
Precision (0x00) S
cale B
ound Size (0x01)
Temperature Filter Upper Bound
Thermostat Reporting Filter Report Command Definition
7
6
5
4
3
2
1
0
Command Class = COMMAND_CLASS_CONFIGURATION
Command = CONFIGURATION_SET
Parameter = 0x0A
Temperature Filter Lower Bound
Temperature Filter Upper Bound
Parameter (8-bit)
The parameter is set to 10 (0x0A) for the temperature reporting filter.
Default (1-bit)
If the default bit is set, the upper bound is zero (0) and the lower bound is 124. This
disables the filter.