The temperature of gases exiting this type of boiler is lower than the temperature exiting the standard
solid fuel boilers. This can lead to the occurrence of condensate if the boiler is not properly used, and
therefore make sure to carefully read the section
STARTING AND CLEANING OF THE BOILER;
it
is also recommended to install a mixing valve on the boiler return line.
For the optimal utilization of energy and comfort during use (number of fuelling is reduced to the
absolute minimum, once to twice a day), the additional installation of heat storage is recommended. For
the 1kW boiler, it is recommended to use 55l heat storage, so that, together with our PK 18, the ideal
accumulation amounts to 1000l.
The use of specified fuels implies automatic control of the main operating parameters. The work is
regulated using the automation placed in the upper part of the boiler, which is used to regulate the work
of the motors that operate flaps for primary and secondary air
(Figure 1c).
Figure 1c. Motors for primary and secondary air flaps
The rated power of the pyrolytic PK 18 boiler is 18kW.