background image

Installation Manual 

SYSTEM BOILER  – Cod. 99951NA – November  2002

 

 

 

VT

1

2

BLACK

BLACK

BROWN

LIGHT BLUE

YELLOW/GREEN

BLACK

BROWN

YELLOW/GREEN

LIGHT BLUE

TA

TA

5

TA

L

N

OR

N

L

OR

1

2

3

4

5

4 3

2 1

M

M

TA

PT

TA

OR

L

N

N

L

OR

TA

PT

PT

re

d

ye

llo

w

bl

ue

br

ow

n

re

d

ye

llo

w

bl

ue

br

ow

n

SHUKO

PLUG

MAINS

NOT

APPLICABLE

FOR U.K.

ELECTRICAL CONNECTIONS  

 
The boiler works with 230 V 50 Hz AC cu

rrent 

and has maximum input of 150 W. Connection to 
the electrical mains must be performed with a 
device having an omnipolar opening of at least 3 
mm. Make sure the live and neutral connections 
conform to the diagram. 

A secure earth 

connection is compulsory.

 

 

IMPORTANT

 

 
If you need to replace the power supply cable, 
use cable having the same characteristics: (HO5 
W-F) 3x1.5 with maximum external diameter 9 
mm.). Connect to the terminal block located in the 
instrument panel as follows: 
 
A.   Turn off the electrical power supply at the 

mains. 

B.   Remove the boiler front casing. 
C.   Undo the two side screws on the panel using 

the phillips screwdriver VT and turn it to the 
position shown in fig.1 (pos. 1). 

D.   After pulling the panel downwards, undo the 

four rear screws on the housing and open the 
electrical control box by lifting the cover as 
shown in fig.1. 

E.   With the electrical control box now open 

make the following connections: 

• 

Connect the yellow/green wire to the terminal 
marked with the earth symbol “   “  (see 
fig.1). 

• 

Connect the blue wire to the terminal marked 
with the letter “N”. 

• 

Connect the brown wire to the terminal 
marked with the letter “L”. 

 

CONNECTION OF ROOM THERMOSTAT 

 
NOTE

: use low voltage room thermostats only.   

 
The thermostat wire must not be placed in the 
channel containing high tension wires, but must 
have its own line  
The room thermostat lead must not exceed 50m 
n length; minimum section 0.5 mm.  

 

Connection

: after carrying out the operations 

described on page 15, proceed as follows: 
A.   Insert the room thermostat lead into the 

entry point on the electrical control box 
along with all the other leads on the boiler. 

B.   Move  the  bridge 

PT

 (see fig.1)  from 

terminal 

TA

 to the free one next to it. 

C.   Insert the thermostat wires (fig.2) one in 

terminal 

TA

 and the other in the one next to 

it occupied by bridge 

PT

 which you have just moved. 

If a timer is fitted as well as a room thermostat, carry out the electrical connections for the timer according to the indications in figures 3 (tipe 
clock + room thermostat) and 4 (time clock only).

 

Fig. 1 

Fig. 5 

Fig. 4 

Fig. 2 

Fig. 7 

Fig. 6 

Fig. 3 

Summary of Contents for RS 30 E

Page 1: ...Specification RADIANT BRUCIATORI S p A Montelabbate PU ITALY By Technical Department INSTALLATION AND MAINTENANCE MANUAL FOR GAS FIRED ONLY HEATING WALL HUNG BOILERS SYSTEM BOILERS Model RS 20 E RS 2...

Page 2: ......

Page 3: ...QUIREMENTS page 5 BOILER INSTALLATION page 7 ELECTRICAL CONNECTIONS page 9 15 16 BOILER CONTROL PANEL page 10 STARTING UP THE BOILER FOR THE FIRST TIME page 10 REGULATING THE GAS PRESSURE page 12 MULT...

Page 4: ...an expansion vessel 2 WARNINGS REGARDING INSTALLATION Warranty expires 12 months from date of installation and in all cases no later than 18 months from date of construction First start up must be pe...

Page 5: ...KCal h 9450 12900 14560 Kw 11 15 16 90 BTU hr 37498 51187 57774 Max working pressure heating bar 3 3 3 Max working pressure water bar 6 6 6 Min working pressure heating bar 0 3 0 3 0 3 Max heating tem...

Page 6: ...60 rotation It allows the flue exhaust into a flue duct and the air intake directly from an external wall N B To insert a bend in the flue reduce total flue length by 1 5 m R RETURN G GAS 1 2 F COLD W...

Page 7: ...tem with 360 rotation It allows the flue exhaust into a flue duct and the air intake directly from an external wall N B To insert a bend in the flue reduce total flue length by 1 5 m R RETURN G GAS 1...

Page 8: ...1988 Pipework that supplies the boiler must be a 22 mm ininterrupted supply from meter to the isolation cock of the boiler The complete installation must be tested for soundness as described in the a...

Page 9: ...ulted Where the lowest part of the terminal is fitted less than 2m 6 6ft above a balcony above ground or above a flat roof to which people have access the terminal MUST be protected by a purpose desig...

Page 10: ...ary pipe connections WATER CONNECTIONS To facilitate installation the boiler is equipped with a fittings kit IMPORTANT Before connecting the heating system pipes carefully clean the system to prevent...

Page 11: ...e temperature falls to 5 C Heating sensor and 4 C Hot water sensor and protects the boiler down to 2 C external temperature To protect the internal Radiators a room thermostat or remote control must b...

Page 12: ...r screws on the housing and open the electrical control box by lifting the cover as shown in fig 1 E With the electrical control box now open make the following connections Connect the yellow green wi...

Page 13: ...e gas cock and check the gas seals making sure the counter shows no sign of leaks in any case double check by using a soapy solution and eliminate all eventual leaks The checking procedure for the gas...

Page 14: ...gnition procedure in any case wait 3 minutes before turning the boiler off and on again then try to ignite it once more calibrate the boiler after carrying out this operation return the panel to its c...

Page 15: ...P1 MAX HEAT trimmer to the minimum heat by turning it counter clockwise regulate the minimum pressure by turning the P2 MIN GAS trimmer see the table below for calibration pressures on completion set...

Page 16: ...for gas leaks each time gas connections are dismantled and reassembled d replace the gas setting plate that indicates the type of gas and nominal pressure for the boiler When converting the boiler to...

Page 17: ...IRCULATING PUMP RSL 15 6 5 GAS VALVE VK4105 6 LT 6 EXPANSION VESSEL 7 3 BAR SAFETY VALVE 8 BURNER 13 R 9 BURNER 17 R 10 HEATING SENSOR 11 WATER PRESSURE SWITCH 12 WATER PRESSURE GAUGE 13 LIMIT THERMOS...

Page 18: ...CLOCK ROOM THERMOSTAT SUMMER WINTER SWITCH TA E I ER EA OR IMPORTANT RESPECT LIVE NEUTRAL POLARITY 19 POWER SUPPLY TERMINAL BLOCK 16 Switch E I IG 18 17 N L M2 7 5 6 9 8 PAC blue black TF 1 2 black br...

Page 19: ...10 R6 M7 RV C 35 M7 33 EV C3 RV D6 M7 32 26 LB M5 TL 8 7 6 5 4 3 1 2 24 M5 ROOM SEALED WIRING DIAGRAM RT LOW VOLTAGE CIRCUIT MAX HEAT MIN GAS T HEAT T SAN THERMOSTATS MODULATION BLOCK SPIA 1 BAR SPIA...

Page 20: ...ption in the instruction manual for the boiler When dismantling the boilers casing be careful when removing the side panels after having removed the front panel the side panels are removed by undoing...

Page 21: ...Installation Manual SYSTEM BOILER Cod 99951NA November 2002 18 SHORT LIST...

Page 22: ...TA02B101 B1203 Technical Specification RADIANT BRUCIATORI S p A Montelabbate PU ITALY ENGLISH USER MANUAL Model RS 20 E 40 60 TYPE C ROOM SEALED Model RS 24 E 70 90 TYPE C ROOM SEALED...

Page 23: ...the boiler in efficient and safe operating condition carefully follow the instructions listed below Have normal maintenance performed at least once a year by one of our authorised service centres a fe...

Page 24: ......

Page 25: ...LET HAVE BEEN CAREFULLY PREPARED BUT WE RESERVE THE RIGHT TO MAKE CHANGES AND IMPROVEMENTS IN OUR PRODUCTS WHITCH MAY AFFECT THE ACCURANCY OF THE INFORMATION CONTAINED IN THIS LEAFLET E OE ALL RIGHTS...

Page 26: ......

Page 27: ......

Page 28: ......

Page 29: ......

Reviews: