REGULATION INSTRUCTIONS
TA05A140.A0307
34
P
ARAMETER
17
–
M
INIMUM
F
AN
S
PEED
S
ETTING
Not applicable
P
ARAMETER
18
–
M
AXIMUM
F
AN
S
PEED
S
ETTING
Not applicable
P
ARAMETER
19
–
M
INIMUM
F
AN
S
PEED
S
ETTING
C
ENTRAL
H
EATING
M
ODE
6. Use buttons ‘+’ o ‘-’ to modify the value of the parameter between:
min = 33 ; max = value of parameter 18.
The default value is:
- 66 Hz for Natural Gas;
- 60 Hz for L.P.G.;
7
.
Press and release button ‘S’ to confirm. The parameter number
(19) will appear in the display.
8. Switch off the appliance and switch it back on again to render
the new parameter operative.
P
ARAMETER
20
–
M
AXIMUM
F
AN
S
PEED
S
ETTING
C
ENTRAL
H
EATING
M
ODE
6. Use buttons ‘+’ o ‘-’ to modify the value of the parameter between:
min = value of parameter 17; max = 202 Hz.
The default value is:
- 162 Hz for Natural Gas;
- 149 Hz for L.P.G.;
7
.
Press and release button ‘S’ to confirm. The parameter number
(20) will appear in the display.
8. Switch off the appliance and switch it back on again to render
the new parameter operative.
S
S
S
S
S
S
S
S
17
55
18
164
19
55
20
164
Summary of Contents for RK 25