2.2.8. TECHNICAL DATA
Model
R1K 34
Maximum nominal heat capacity in heating circuit
MJ/h
13
5
Minimum nominal heat capacity in heating circuit
MJ/h
16
Useful thermal power - 60/80°C
kW
33,35
Minimum useful thermal power - 60/80°C
kW
3,94
Useful thermal power - 30/50°C
kW
36,19
Performance at 100% Pn - 60/80°C
%
98,08
Performance at 30% Pn - return 47°C
%
102,14
Performance at 30% Pn - return 30°C
%
108,57
Performance at 100% Pn - 30/50°C
%
106,43
Maximum combustion Performance
%
97,6
Fumes temperature at nominal heat capacity
°C
69,4
Fumes temperature at minimum heat capacity
°C
61,3
CO2 at nominal heat capacity - Natural Gas
%
9,45 - 9,25
CO2 at minimum heat capacity - Natural Gas
%
9,05 - 8,85
CO2 at nominal heat capacity - Universal LPG
%
10,55 - 10,35
CO2 at minimum heat capacity - Universal LPG
%
9,90 - 9,7
CO at nominal heat capacity
ppm
75
Fumes mass at nominal heat capacity
g/s
14,96
Fumes mass at minimum heat capacity
g/s
1,88
NOx class
class
6
Weighted Nox (0% O2) mg/kWh
mg/kWh
55
Heating circuit
Adjustable heating temperature
°C
30-80 / 25-45
Maximum operating water temperature for heating circuit
°C
95
Maximum operating pressure for heating circuit
kPa
300
Minimum operating pressure for heating circuit
kPa
30
Capacity of the system expansion vessel
litres
8
Dimensional characteristics
Width
mm
410
Depth
mm
330
Height
mm
642
Gross weight
Kg
44
Water connections
Flow
Ø
3/4”
Cold water
Ø
1/2”
Gas
Ø
3/4”
Return
Ø
3/4”
Flue fittings
Maximum electric fan pressure available
Pa
91
Minimum electric fan pressure available
Pa
5,8
Max discharge length Ø60/100 - Hor Co-ax
m
2
Max discharge length Ø80/125 - Hor Co-ax
m
10
Max discharge length Ø50 - Hor duct
m
2
Max discharge length Ø60 - Hor duct
m
12