Symbol Descriptions 

 

The CE mark and Notified Body 

Registration Numbers, the requirement 

of Annex II from Medical Device 

Directive 93/42/EEC are met. 

 

Please do not dispose of the product in the 

household waste at the end of its useful life. 

Disposal can take place at appropriate collection 

points provided in your country.

 

 

Authorized representative 

in the European 

community 

 

Caution 

 

Please read the instructions for use 

 

Manufacturer 

 

BF type applied part 

 

To protect the environment, dispose of empty 

batteries at your retail store or at appropriate 

collection sites according to national or local 

regulations.

 

 

Paper Recycling 

IP22

 

Classification for water ingress and 

particulate matter. 

 

 

 

 

 

Manufacturer’s declaration-electromagnetic emissions 

The TH5xy series is intended for use in the electromagnetic environment (for home healthcare) specified below. 

The customer or the user of the TH5xy series should assure that it is used in such an environment. 

Emission test 

Compliance 

Electromagnetic environment-guidance

 

(for home healthcare environment) 

RF emissions   

CISPR 11 

Group 1 

The TH5xy series uses RF energy only for its internal function. Therefore, its RF emissions are 

very low and are not likely to cause any interference in nearby electronic equipment. 

RF emissions   

CISPR 11 

Class B 

The TH5xy series is suitable for use in all establishments, including domestic establishments and 

those directly connected to the public low-voltage power supply network that supplies buildings 

used for domestic purposes. 

 

Manufacturer’s declaration-electromagnetic immunity 

The TH5xy series is intended for use in the electromagnetic environment (for home healthcare) specified below. 

The customer or the user of the TH5xy series should assure that it is used in such an environment. 

Immunity test 

IEC 60601   

test level 

Compliance level 

Electromagnetic environment-guidance            

(for home healthcare environment) 

Electrostatic discharge(ESD) IEC 

61000-4-2 

Contact:±8 kV   

Air±2 kV,±4 kV,±8 kV,±15 kV 

Contact:±8 kV   

Air±2 kV,±4 kV,±8 kV,±15 kV 

Floors should be wood, concrete or ceramic tile. If floors 

are covered with synthetic material, the relative humidity 

should be at least 30% 

Power frequency(50, 60 Hz) 

magnetic field IEC 61000-4-8 

30 A/m 

50 Hz or 60 Hz 

30 A/m 

50 Hz and 60 Hz 

The TH5xy series power frequency magnetic fields should 

be at levels characteristic of a typical location in a typical 

home healthcare environment. 

 

Manufacturer’s declaration-electromagnetic immunity 

The TH5xy series is intended for use in the electromagnetic environment (for home healthcare) specified below. 

The customer or the user of the TH5xy series should assure that is used in such and environment. 

Immunity test 

IEC 60601 test level 

Compliance level 

Electromagnetic environment-guidance    

(for home healthcare environment) 

Radiated RF   

IEC 61000-4-3 

10 V/m 

80 MHz – 2,7 GHz   

80 % AM at 1 kHz 

10 V/m 

80 MHz – 2,7 GHz   

80 % AM at 1 kHz   

Recommended separation distance: 

d = 1,2 

 

d = 1,2 

  

80MHz to 800 MHz 

d = 2,3    800MHz to 2,7 GHz   

 

Where

 P

 is the maximum output power rating of the 

transmitter in watts (W) according to the transmitter 

manufacturer and 

is the recommended separation 

distance in metres (m). 

 

Field strengths from fixed RF transmitters, as 

determined by an electromagnetic site survey, 

a

 

should be less than the compliance level in each 

frequency range.

 

Interference may occur in the vicinity of equipment 

marked with the following symbol: 

 

NOTE1      At 80 MHz and 800 MHz, the higher frequency range applies. 

NOTE2      These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people. 