Power O F F
Power O N (Air)
Power O N (F loor)
Dual Touch Programmable Thermostat - User Guide
Models - W3115DT / W3115DT AU / W3115DT Black
1
Description
1.1
The Dual touch programmable thermostat has three
temperature control modes:
A mode:
F mode:
AF mode:
controls the ambient air temperature
controls the floor temperature using an
external
sensor
controls the ambient air temperature
maintains the floor temperature within
desired limits using an external
temperature sensor
Time
Day
Mode
A/ F / AF mode
Period display
Power button
Menu button
Check button
Setting function
Temperature
Return button
Preset temperature
Adjustment buttons
Power off the thermostat when not in use (eg summer).
This will not affect the time and temperature settings.
After Power-on, the
shows the Power O F F
display (see image 1)
Press the Power button for the Standby screen
(image 5)
Press the Power button again for the Power O N screen.
Press the Power button for 3 seconds for the Power
O F F screen (this will stop the scheduling and the towel
rail mode).
1
2
3
4
5
1.2
Preset Temperatures
The thermostat has 3 modes of temperature operation:
Comfort temperature
E conomy temperature
Vacation temperature
The following table shows the intended use and the
default setting of each of the preset temperatures.
Mode
A/ AF mode F mode Towel Rail
Comfort (when at home) 21° C
24 ° C
E conomy (when asleep 17 ° C
16 ° C
or away from home
Vacation (during a
10° C
10° C
prolonged absence)
As per heated
towel rail
specifications
Modes of Operation
2
2.1
Automatic mode
The thermostat has 4 modes of operation:
- U se the scheduling time to control
temperature.
Programmed Schedule
The schedule consists of 4 periods per day, which
represents a typical week day. Y ou can program the
thermostat to skip the
periods that do not apply to your
situation. F or example, you can skip periods 2 and 3 for
the weekend.
Period Temperature MO N TU E W
E D THU F RI SAT SU N
2.2
Manual Mode
-
The temperature must be set manually.
Y ou can modify the preset temperature by pressing
when the thermostat is in automatic
mode. The new temperature will be used until the
beginning of the next period.
2.3
-
The therm stat uses the vacation
preset temperature to control this mode.
Vacation Mode
2.4
-
The following table shows the
intended use and the default setting of each of the preset
times.
Towel Rail Heating Mode
Power O N (Air+ F loor) Standby
5:3 0 5:3 0 5:3 0 5:3 0 5:3 0 6 :00 6 :00
8 :00 8 :00 8 :00 8 :00 8 :00 9 :00 9 :00
18 :00 18 :00 18 :00 18 :00 18 :00 18 :00 18 :00
21.3 0 21.3 0 21:3 0 21:3 0 21:3 0 21:3 0 21:3 0
Period Temperature MO N TU E W
E D THU F RI SAT SU N
As per heated
towel rail
specifications
5:3 0 5:3 0 5:3 0 5:3 0 5:3 0 6 :00 6 :00
8 :00 8 :00 8 :00 8 :00 8 :00 9 :00 9 :00
18 :00 18 :00 18 :00 18 :00 18 :00 18 :00 18 :00
21.3 0 21.3 0 21:3 0 21:3 0 21:3 0 21:3 0 21:3 0
Comfort
Economy
Comfort
Economy
F
F
Floor set temperature Air+Floor set temperature
MON
�
C
�
C
Set
Floor
MON
�
C
C
�
Set
Air
Air set temperature
MON
�
C
�
C
Set
Air