7
4. Troubleshooting
In the event of overheating, the safety device on the appliance automatically disabled the heating
elements and motor. As a result, the heater stops working and the alarm light switches on. In this case:
-
Turn off the fan heater and allow it to cool down for about 15/20 minutes.
-
Make sure the dust filter is not totally obstructed and clean if necessary. Remember to put it back
again afterwards.
-
Eliminate any other possible reasons for overheating (e.g.: obstructions in front of the air inlet/outlet
grilles, build-ups of dirt).
-
Turn on the fan heater again and check it works correctly.
5. Maintenance
This product does not require any special maintenance.
Clean the product with a dry cloth once every 6 months.
If the product requires repairing, contact an authorised technical service centre.
When replacing the power cable, use a 2x1,00mm
2
H05VV-F HAR type. This operation must be
performed by qualified personnel and never by the end user in order to avoid damaging the appliance
and jeopardising personal safety.
6. Legal notice
Environment and recycling
Please help us to protect the environment by disposing of the packaging in accordance with the
national
regulations for waste processing.
Recycling of obsolete appliances
Appliances with this label must not be disposed off with the general waste. They must be
collected separately and disposed off according to local regulations.