background image

True to the Music

Radial Engineering Ltd.

8ox & 8cx Owner’s Manual

MOUNTING AND TERMINATING THE 8CX 

The distinctive ‘skeletal’ frame is easy to mount using the four, pre-drilled mounting feet. When terminating the perforations around the 
frame offer cable management tie-downs and built-in stand-offs allow cables to pass underneath. Tie off cable bundles at the frame to 
provide strain relief at the WAGO connectors.

To ensure proper shielding from external noise it is important that the enclosure be bonded to ground (earth). Conduit installed by 
electrical trades is usually bonded to the buildings main ground which is ideal for the 8cx. If you are mounting in another type of metal 
enclosure ensure it has a connection to ground. If you are unsure, consult your local electrical codes.

Connecting the WAGO Terminals 

The 8cx install splitter employs four WAGO spring clamp terminals to facilitate quick on-site connection. These accept wire gauges 
from 14awg to 28awg and feature a clamping action that embeds the wire for a solid and dependable contact. For neat installations 
that facilitates long term servicing, it’s a good idea to plan out the cable paths in advance. Always tie-off cable bundles to the 8cx frame 
for strain relief. 

Strip off about a quarter inch of insulation from the wire.  A small screwdriver is used to push open a terminal clamp on the WAGO 
connector. Insert the wire lead and let go. The wire is clamped in.  Visually inspect where the wire enters the WAGO connector and 
ensure that it is inserted far enough that no bare copper is exposed or can touch the wires of other channels. The pin-out legend is silk 
screened on the PCB above each WAGO connector.

INTERNAL GROUNDING OPTIONS

8cx FEATURE SET

1. 

Skeleton Frame

 - The 9.5” x 5” frame is constructed of 

14-gauge steel and serves several functions. It’s built in 
stand-offs allow cable to pass underneath. It can be used 
as a cable tie-down point on four sides.

2. 

Radial Transformer

 - Each transformer is mounted directly 

on the PCB in close proximity to the input for the shortest 
possible signal path.

3. 

WAGO Terminal

 - Used for all the I/O connection, the 

WAGO terminal uses a spring clip to clamp down on the 
wire for a secure termination. 

4. 

Ground Lift DIP Switch

 - Each channel feature a ground 

DIP switch that disconnects the signal ground at the DI-
RECT WITH LIFT output. It may be used to break ground 
loops between devices connected to the DIRECT and aux-
iliary DIRECT WITH LIFT outputs.

1

2

3

+ - G

1

+ - G

2

+ - G

3

+ - G

4

+ - G

5

+ - G

6

+ - G

7

+ - G

8

1

2

4

5

6

7

8

9

10

3

5. 

Inputs

 - Eight channels of balanced signals connect to the 

8cx input via WAGO spring terminal.

6. 

Legends

 - The PCB is clearly marked with termination 

information above each WAGO terminal. All information 
required for terminating is screened right on the PCB.

7. 

Direct Output

 - This output passes signal straight through 

the 8cx and is usually the return path for phantom power.

8.

 Direct with Lift

 - This auxiliary output is wired in parallel 

with the DIRECT output. The signal ground may be lifted 
using the DIP switch to eliminate hum from ground loops. 

9. 

Isolated Output

 - This output is transformer isolated to 

block hum and buzz caused by ground loops.

10. 

Military Grade PCB

 - The dual layer circuit board is man-

ufactured to military standards with plated through holes.

Referring to the pins on an XLR connector:
• Connect pin-1 (GROUND) to the G terminal. 
• Connect pin-2 (HOT) to the + terminal.
• Connect pin-3 (COLD) to the - terminal.

Push the white tab to 
open spring clamp.

Insert bare wire here.
Repeat for each connection.

9

Summary of Contents for 8cx

Page 1: ...accompany any request for work to be performed under this limited warranty This limited warranty shall not apply if the product has been damaged due to abuse misuse misapplication accident or as a res...

Page 2: ...nce are subject to change without notice Radial Engineering Ltd 1638 Kebet Way Port Coquitlam BC V3C 5W9 tel 604 942 1001 fax 604 942 1010 email info radialeng com web www radialeng com www radialeng...

Page 3: ......

Page 4: ...It s most common in sound reinforcement and live recording when the on stage microphones must be split to feed two mixing consoles When done improperly splitting a signal can dull frequency response l...

Page 5: ...ormer eliminating noise caused by ground loops Once the loop is complete there is the electrical potential for DC voltage to flow through it This potential is caused by the interaction between devices...

Page 6: ...Isolated Output The ISOLATED outputs uses eight precision audio isolation transformers to decouple the mic signals from the DIRECT outputs This output may be patched to a separate audio sys tem withou...

Page 7: ...lt this switch is factory set to lifted allowing the chassis to float ungrounded and should remain this way unless a specific grounding scheme requires the signal ground to be tied to the chassis 10 1...

Page 8: ...r then mates with the socket Pin termination for the Euroblock terminals are clearly marked on the rear panel Referring to the pins on an XLR connector 1 2 3 G G G G Connecting the DB 25 I O The DB 25...

Page 9: ...three consoles to an 8ox The MAIN PA console connects to the DIRECT output and the MONITOR console to the auxil iary DIRECT with LIFT output In order to avoid hum and buzz from ground loops these cons...

Page 10: ...ISOLATED output for that channel Internal Chassis Ground Lift All Channels All tconnectors are 100 isolated from the steel chassis allowing chassis and signal ground to be kept separate However an sin...

Page 11: ...8cx splitters are mounted in an electrical box located in a utility room or under the stage The 8cx is designed to fit in standard size NEMA electrical junction boxes Six 8cx splitters can easily fit...

Page 12: ...AGO connector INTERNAL GROUNDING OPTIONS 8cx FEATURE SET 1 Skeleton Frame The 9 5 x 5 frame is constructed of 14 gauge steel and serves several functions It s built in stand offs allow cable to pass u...

Reviews: