background image

True to the Music

Radial Engineering Ltd.

8ox & 8cx Owner’s Manual

8OX FEATURE SET

1. XLR Inputs

 - Front panel female XLR jacks allow easy 

connection of individual signals. Rugged, glass-reinforced 
nylon construction for reliable connections.

2. PAD -20dB

 - Prevents transformer overload when con-

necting high output devices. Only the ISOLATED output is 
affected by the PAD.

3. Front panel Lift switch

 - Disconnects the ground path at 

the DIRECT WITH GROUND LIFT auxiliary output. Using 
the front panel ground lift can eliminate ground loop noise 
between equipment connected to the 8ox direct outputs.

4. Easy ID label zones 

- For dry-erase markers or wax pencil 

identifi cation. Handy when using several 8ox at a time.

5. Military Grade PCB

 - The dual layer circuit board is 

manufactured with plated through holes and secured with 
8 standoffs.

6. Transformers

 - Each transformer is mounted directly on 

the PCB in close proximity to the input for the shortest 
possible signal path. Choice of standard Radial or optional 
Jensen transformers.

7. Heavy-duty Switches

 - Front panel switches are metal 

encased and rated at 20,000 operations.

8. Internal Ground Lift

 -  Each channel features an internal 

switch that, by default, is set to “lifted” so the transformer 
can isolate ground potential voltages. It may be used by 
system designers to accommodate specifi c  grounding 
schemes when desired.

9. Internal Chassis Ground Lift

 - Input connectors are 

100% isolated from the chassis, but an internal switch is 
provided to connect signal ground (pin-1) to the chassis 
without modifying the 8ox. By default, this switch is factory 
set to “lifted” allowing the chassis to “fl oat” ungrounded and 
should remain this way unless a specifi c grounding scheme 
requires the signal ground to be tied to the chassis.

10. 14-Gauge Chassis

 - Made extra tough with heavy gauge 

steel and welded corners to provide excellent shielding 
and durability. Finished in baked enamel.

11. Isolated Output

 - This output is transformer isolated 

to block noise caused by ground loops and is wired in 
parallel to DB-25 and Euroblocks terminals.

12. Direct With Ground Lift

 - This is an auxiliary output 

 

wired in parallel with the DIRECT output. The signal 
grounds may be disconnected using the front panel LIFT 
switch. This output is wired parallel to the DB-25 and Eu-
roblocks terminals.

13. DB-25 Pin-out Diagram

 - The pin-out for the female DB-

25 connector is diagramed on the rear panel. All DB-25 
connectors follow the Tascam standard for eight channel 
analog signal interface.

14. Euroblock Sockets 

- These panel sockets receive 12-pin 

Euroblock screw terminals. Each Euroblock connects four 
channels with bare wire termination and facilitate custom 
options like interfacing a connector panel or multi-pin 
disconnect. Euroblocks screw terminals are optional and 
must be ordered separately. (Radial order # R800 8050)

15. Direct Output

 - This output passes signal through the 

8ox and provides the return path for phantom power. 
This output is wired parallel to the DB-25 and Euroblocks 
terminals.

16. Rear Inputs

 - The rear panel DB-25 and Euroblock inputs 

connect all eight channels and are wired parallel to the 
front XLR connectors. 

17. Chassis Ground - 

Ground screw connection point used 

in conjunction with the internal chassis lift switch to bond 
the 8ox to earth. 

1

2

3

4

5

6

7

8

9

10

11

12

13

15

16

17

14

4

Summary of Contents for 8cx

Page 1: ...accompany any request for work to be performed under this limited warranty This limited warranty shall not apply if the product has been damaged due to abuse misuse misapplication accident or as a res...

Page 2: ...nce are subject to change without notice Radial Engineering Ltd 1638 Kebet Way Port Coquitlam BC V3C 5W9 tel 604 942 1001 fax 604 942 1010 email info radialeng com web www radialeng com www radialeng...

Page 3: ......

Page 4: ...It s most common in sound reinforcement and live recording when the on stage microphones must be split to feed two mixing consoles When done improperly splitting a signal can dull frequency response l...

Page 5: ...ormer eliminating noise caused by ground loops Once the loop is complete there is the electrical potential for DC voltage to flow through it This potential is caused by the interaction between devices...

Page 6: ...Isolated Output The ISOLATED outputs uses eight precision audio isolation transformers to decouple the mic signals from the DIRECT outputs This output may be patched to a separate audio sys tem withou...

Page 7: ...lt this switch is factory set to lifted allowing the chassis to float ungrounded and should remain this way unless a specific grounding scheme requires the signal ground to be tied to the chassis 10 1...

Page 8: ...r then mates with the socket Pin termination for the Euroblock terminals are clearly marked on the rear panel Referring to the pins on an XLR connector 1 2 3 G G G G Connecting the DB 25 I O The DB 25...

Page 9: ...three consoles to an 8ox The MAIN PA console connects to the DIRECT output and the MONITOR console to the auxil iary DIRECT with LIFT output In order to avoid hum and buzz from ground loops these cons...

Page 10: ...ISOLATED output for that channel Internal Chassis Ground Lift All Channels All tconnectors are 100 isolated from the steel chassis allowing chassis and signal ground to be kept separate However an sin...

Page 11: ...8cx splitters are mounted in an electrical box located in a utility room or under the stage The 8cx is designed to fit in standard size NEMA electrical junction boxes Six 8cx splitters can easily fit...

Page 12: ...AGO connector INTERNAL GROUNDING OPTIONS 8cx FEATURE SET 1 Skeleton Frame The 9 5 x 5 frame is constructed of 14 gauge steel and serves several functions It s built in stand offs allow cable to pass u...