Appendix A: Relay Switch Option

 

 

Overview:

 

 

The TC

-

600 Interface board allows 

 

users to connect the TC

-

600 Radarsign 

to external devices. 

 

 

The interface board has two relay 

 

outputs (connectors shown in green) 
and one input (connector shown in 
blue). 

 

 

The Relay Outputs can be used to 
power or trigger external devices; the 
Input Trigger can be used to change 
the sign

s display configuration based 

on the presence or absence of an external signal.

 

 
 

Input Trigger:

 

The Interface Board has an input which will change the radar speed sign

s configuration based on external 

input. The input is universal; it can be triggered by applying any voltage from 12 VDC –

 120 

VAC across 

the input screw terminals. The input trigger latches on for two seconds, which allows flashing beacon 
lamps to be used to trigger an input event. As long as the input sees a voltage above 12 V at least once 
every two seconds, the trigger will remain active. 

 

 

When using the Input Trigger with DC sources, polarity is important, ensure the 

 

positive wire leads to the screw terminal marked with a (+).  When using the Input 
Trigger with an AC device, polarity does not matter.

 

 

 

 

To use the trigger input, first set up the 

Trigger Configuration 

by 

 

clicking the 

Trigger

 link at the bottom of the 

HOME 

configuration screen.

 

 
 
 
 
 
 
 
 

 
 

This link leads to a configuration page nearly identical to the 

HOME configuration page

 

 

Set the 

Trigger Configuration 

as desired.

 

 

Then click 

Set Config

 and 

Return HOME 

to return to the 

HOME 

 

configuration page.

 

 

 

HOME 

configuration page

 

Relay

 

Input

 

Relay

 

Outputs

 

T

o

 CP

U

 

Summary of Contents for TC-400

Page 1: ...1 of 16 Radar Speed Sign Operation Manual_MN0025 v21 02 2005 2021 Radarsign LLC All Rights Reserved Radar Speed Sign Operation Manual All Models TC 400 TC 600 TC 1000...

Page 2: ...2 of 16 Radar Speed Sign Operation Manual_MN0025 v21 02 This Page Left Blank...

Page 3: ...the Interface Board pg 15 Warranty pg 16 ______________________________________________________________________________ If you experience any trouble setting up your sign please refer to our Troubles...

Page 4: ...must accept any interference received including interference that may cause undesired operation Customer Support Call 678 965 4814 or 678 520 5152 or email customerservice radarsign com Shipping Addre...

Page 5: ...d equipment To reduce the risk of burns or other acid related injury resulting from exploding batteries Always use the recommended charging systems with this product To reduce the risk associated with...

Page 6: ...o the network say yes You have successfully connected to your radar sign 8 Once connected open your web browser 9 In the address box at the top of your browser enter the following url 10 0 0 1 The con...

Page 7: ...opens it will display the current settings of the radar speed sign The alert settings and advanced functions available will vary depending on the your sign model and the sign options you purchased TC...

Page 8: ...PH KPH settings Select the setting for your country standard Display Configuration 4 Display Enabled Turns the display on or off UNCHECK if you wish to collect traffic statistics in Stealth Mode to ge...

Page 9: ...d Accessories High Intensity LEDS Strobes If you have purchased a sign with strobes select a display Simulated camera flash flash once Strobe 3 rapid flashes Strobe Alternating The choice of Strobe Al...

Page 10: ...the timers 5 Possum Switch A vandalism discouraging feature that causes the sign to play dead after it detects a severe impact If this feature is enabled the sign will disable all outward signs of act...

Page 11: ...your sign enter the Relay options desired for this time period This feature is only available on a TC 500 TC 600 and TC 1000 7 Be sure to save the settings by clicking the Set Config button This refr...

Page 12: ...12 VDC 120 VAC across the input screw terminals The input trigger latches on for two seconds which allows flashing beacon lamps to be used to trigger an input event As long as the input sees a voltag...

Page 13: ...acon Mode the two output relays will alternate at 1 Hz each relay closed for 0 5 seconds then opened for 0 5 seconds This mode is intended to be used in conjunction with school zone beacon lamps Speed...

Page 14: ...Enabling these options forces the relay output s on for the entire duration of the timer In the example shown the relays would be in alternating beacon mode every Monday Wednesday and Friday from 8 1...

Page 15: ...e shown Beacon Mode is enabled for Alert 2 If a car is traveling over 30 MPH the Alert 2 settings take over and the Hyper Alerts will activate Servicing the Interface Board The only user serviceable p...

Page 16: ...is responsible for inbound shipping Radarsign will pay for return shipping to the customer for the entire warranty period if customer is located within North America Customers from a country outside o...