Chapter 3
WaveGuide system commissioning
With all system components correctly connected as described in the previous chapter,
the processing unit can be configured using the following steps (explained in the current
chapter):
1. Connect the WaveGuide processing unit to a computer.
2. Become an authorized user.
3. Configure the system.
4. Perform a system check.
5. Configure the distribution of data.
The display on the processing unit shows system information and measured parameters and
is controlled using the buttons on the front:
• Left and right: To switch between groups.
• Up and down: To switch between items within each group.
• OK: To confirm mounting and unmounting of USB data storage.
The processing unit display contains the following groups and items:
• Parameters
–
Scrolls through selected parameters (Appendix 1: System parameters)
• Network
–
Host name
–
IP address
• System information
–
Date and time
–
Uptime
–
Software version
• USB storage (only appears when USB device is connected)
–
State
–
Mount USB disk?/ Unmount USB disk?
15