![rada Safetherm Product Manual Download Page 12](http://html1.mh-extra.com/html/rada/safetherm/safetherm_product-manual_3205730012.webp)
12
Panel Mounting
Warning!
Make sure that there are no buried cables or pipes in the wall before
drilling.
21 mm
200 mm
Back Nut
Compression Nut
Inlet
Connector
1.
Temporarily assemble the inlet
connectors with the inlet elbows
tightening both grubscrews with a
2.5 mm hexagonal key.
2.
Mark the positions of the holes for
the inlet connectors on the panel and
then drill two Ø21 mm holes for the
inlet connectors.
3.
Fit the 'O' seal to the rear face of the
inlet connectors then install the inlet
connectors through the Ø21 mm
holes and loosely fit the back nuts.
4.
Install the hot and cold supply
pipework ensuring that the pipe ends
align with the inlet connectors.
5.
Fit the compression nuts and olives
or the flat face connectors onto the
supply pipes and connect the supply
pipes to the inlet connectors.
Confirm that the inlet connectors are
level and the specified distance apart
then use a suitable wrench to tighten
the back nuts.
Note!
Use the flats provided on the
inlet connectors to hold the connectors
in position while tightening the back
nuts.
Inlet
Connector
Heat
Shroud
2.5 mm Hexagonal
Key
Inlet
Elbow
Olive
Grubscrew
'O' Seal
Compression Nut
Olive
Inlet
Connector
Summary of Contents for Safetherm