Fingerprint access for the key safe(WMBB) and key/card safe(CCRB): 

 

If you haven't already had your fingerprint added to the key safe 
system you should plan on having that done on 
any Thursday at 2pm.  If you need to have that done make sure to stop 
by the main desk on first floor of WMBB(or call them at 6-5258) and 
sign up for this so that central security knows to come.   Once your 
training with me is complete I will submit the request for you to have 
access to both units for the keys to access the Xray.  The fingerprinting 
is for the unit in WMBB, it is entirely up to you to get access for that 
unit.  I do strongly encourage access to both units so if one goes down 
you still have access to the other. 
 

4.

 

RAR access:

 

           Since the Xray is housed in the CCRB RAR facility we need to get you        
           access if you don't already have it. Here are the different steps that  
           may need to be taken.  Let me know which one fits your needs and I  
           will send you the correct forms. 

1.

 

If you currently have a mouse protocol and have mice housed in 
CCRB you will not need to do anything further if you have CCRB RAR 
access.  Please contact me if your PI has a protocol and you are 

not

 

on it. 

2.

 

If your PI has a mouse protocol and your lab houses animals at a 

different

 location from CCRB you will need to request RAR access to 

CCRB. You will need to set up a tour with the CCRB area supervisor 
and attend a short training session with him.  The contact info is: 

Max Myers  

[email protected]

.

 

3.

 

If you/PI do not have a mouse protocol and you don't work with mice 
you will need to set up a tour with the CCRB area supervisor and 
attend a short training session with him.  The contact info is: 

Max 

Myers  

[email protected]

.

 

 

5.

 

Hands on training:

 

Once all of the online modules are done contact 

Deb Lins 

(

[email protected])

 to set up a time for the hands on training and 

access verification. 

 
 
 
 
 

Summary of Contents for RS-2000

Page 1: ...egulatory Dose Limit General Hazards Associated with the X Ray Irradiator Safety Instructions Regarding the RS 2000 Irradiator Operating Instructions for the RS 2000 Irradiator 2 More complete and det...

Page 2: ...ct with the body So our next question is What is ionization and why is it a concern All matter is made up of atoms Atoms contain a small central nucleus containing protons which have electrically posi...

Page 3: ...called an ion The process of ionization is illustrated below This freed electron can potentially cause damage to living cells or DNA The damage can be repaired from small amounts of radiation however...

Page 4: ...generate x rays see picture below Basically what happens is that a metal filament is heated up to a very high temperature allowing electrons from the metal to essentially boil off Electrons the small...

Page 5: ...ill I receive from handling irradiated specimens and from using this irradiator As for handling irradiated specimens they do NOT become radioactive after an irradiation and you will not receive any ra...

Page 6: ...s No unauthorized personnel may defeat or override any safety features on the x ray generator collimator or shielding without permission of the manufacturer Rad Source The RS 2000 is to be serviced by...

Page 7: ...Indication Lights show when X rays are being produced Shielded and Interlocked X Ray Tube Chamber to prevent X ray production if panel should be opened Door Handle Double Safety Interlocked to prevent...

Page 8: ...ning module must be documented in order to get Xray access This training is different that the Radiation training orientation you need to complete both Radiation Safety for Radioactive Material Users...

Page 9: ...t Here are the different steps that may need to be taken Let me know which one fits your needs and I will send you the correct forms 1 If you currently have a mouse protocol and have mice housed in CC...

Page 10: ...gaged unit will not operate if not properly closed This can be done after you load your samples animals and set your time 2 Use the key to turn the power on off switch to on the key to power on the un...

Page 11: ...d that over heating can cause the unit to shut down I also have an electric fan in the room that you can set up to bring cooler air from the hall into the room 5 Main Menu The main menu enables the op...

Page 12: ...re two pre programmed warm up cycles labeled NORMAL and EXTENDED Unless you know that the unit hasn t been used for a couple of months select NORMALNORMAL 4 Press START at the bottom of the screen 5 T...

Page 13: ...re typically irradiated on Level 1 i e within the black RAD reflective chamber on the floor of the chamber Place no more than 5 mice in a CLEAN cage Remove food and water from the cage if you have exc...

Page 14: ...ormity is 98 The radiation dose rate is highly dependent upon the distance from the radiation source x ray tube Therefore for certain specimens e g test tubes flasks plates you should lay items horizo...

Page 15: ...S 29M 42S 22M 43S 16M 40S 11M 43S 7M 19S 3 500 35 31M 15S 30M 42S 34M 39S 26M 32S 19M 27S 13M 41S 8M 33S 4 000 40 35M 42S 35M 06S 39M 36S 30M 18S 22M 14S 15M 38S 9M 45S 6 000 60 53M 35S 52M 32S 59M 24...

Page 16: ...an irradiation time in for one programs A B C or D If you have already programmed in an irradiation time go to Step 3 After selecting PROGRAM SETUP the following screen AUTO PROGRAM SETUP will appear...

Page 17: ...afety Cabinet If the BSC is used spray and wipe down all surfaces inside the BSC Repeat with TEC Surf solution c Please dispose of all debris and waste in the waste basket provided d Empty the bleach...

Page 18: ...rrective actions for the RS 2000 Most of the time you will just need to hit clear and continue on If that doesn t work turn off the machine wait 20 seconds and turn it back on If neither of those opti...