Getting started

RipEX2-HS serves as a redundant station equipped with two standard RipEX2 radio modems using a
hot standby functionality. All you have to do to put it into operation is to connect properly all connectors
and configure internal RipEX2 units using a PC and a web browser.

Fig. 1: RipEX2-HS

RipEX2 access defaults: IP 192.168.169.169/24, username: admin, password:

admin or

IP 10.9.8.7

when accessing over the optional USB/ETH adapter or Wifi adapter.

Power on the RipEX2-HS and wait approx. for 25 seconds for the RipEX2 OS to boot. When accessing
over the optional USB/ETH adapter or Wifi adapter, your PC will get its IP settings from the built-in
DHCP server and you have to type https://10.9.8.7 in your browser.

When accessing over Ethernet, set a static IP 192.168.169.x/24 on your PC first, connect your PC to
RipEX2 ETH interface, start your browser and type https://192.168.169.169 in the address line. When
accessing RipEX2 for the first time and using https, you have to accept the https security certificate
issued by RACOM.

Note

Both RipEX2 units are in factory default settings.

RipEX2-HS – © RACOM s.r.o.

6

Getting started

Summary of Contents for RipEX2-HS

Page 1: ...User manual RipEX2 HS version 1 2 2019 11 26 fw 1 3 2 0 www racom eu RACOM s r o Mirova 1283 592 31 Nove Mesto na Morave Czech Republic Tel 420 722 937 522 E mail racom racom eu...

Page 2: ......

Page 3: ...2 Safety distance 28 8 3 Electric power shock hazard 28 8 4 High temperature 28 8 5 RoHS and WEEE compliance 29 8 6 Conditions of Liability for Defects and Instructions for Safe Operation of Equipmen...

Page 4: ...k tray shelf 19 4 3 RipEX2 HS RD RS L profile mount 20 4 4 RipEX2 HS RD RS rack mount kit 21 4 5 RipEX2 HS grounding in a cabinet 22 8 1 EU Declaration of Conformity RoHS WEEE 30 8 2 EU Declaration of...

Page 5: ...or losses of data are rare when wireless devices such as the RipEX2 HS are used in an appropriate manner within a well constructed network RipEX2 HS should not be used in situations where failure to t...

Page 6: ...on the RipEX2 HS and wait approx for 25 seconds for the RipEX2 OS to boot When accessing over the optional USB ETH adapter or Wifi adapter your PC will get its IP settings from the built in DHCP serve...

Page 7: ...ndent power supply Controller takes care of the automatic changeover in case of failure Changeover conditions are widely configurable Since both units are hot standby and use identical MAC addresses a...

Page 8: ...old the controller automatically switches interfaces COM ETH1 ANT if applicable to the second unit and it takes over all functions Since both units are using the same MAC addresses MAC cloning there i...

Page 9: ...ues of RipEX2 which becomes in active these packets are discarded after switch over 2 4 1 Power alarm Power supply of respective unit is Off when the input voltage from the respective power supply to...

Page 10: ...3 Product 3 1 Dimensions 3 1 1 RipEX2 HS 19 rack 3U 442 W 392 D 120 H mm 17 40 W 15 43 D 4 72 H inch Fig 3 1 RipEX2 HS dimensions RipEX2 HS RACOM s r o 10 Product...

Page 11: ...3 1 2 RipEX2 RD 19 rack 3U 442 W 392 D 87 H mm 17 40 W 15 43 D 3 42 H inch Fig 3 2 RipEX2 RD dimensions 11 RACOM s r o RipEX2 HS Product...

Page 12: ...3 1 3 RipEX2 RS 19 rack 3U 442 W 392 D 87 H mm 17 40 W 15 43 D 3 42 H inch Fig 3 3 RipEX2 RS dimensions RipEX2 HS RACOM s r o 12 Product...

Page 13: ...of each connector is the same as with RipEX2 unit and you can find it in RipEX2 manual ETH1 and ETH5 SFP are connected to an internal switch for connection of both ETH to the individual RipEX2 units...

Page 14: ...of the A unit RipEX2 AO Alarm output of the B unit RipEX2 BO Alarm status output indication of an alarm of HS controller S1 Alarm status output indication of an alarm of A unit or and B unit S2 Fig 3...

Page 15: ...ise together with unit in alarm status dark RipEX2 A is not active Green solid Unit A active selected as active by switch A 2 green blinking AUTO mode ready to serve Red solid unit in alarm status Red...

Page 16: ...us on A unit occurs which causes switching to unit B AUTO RipEX2 unit B hard selected it remains active even in case of alarm on unit B B For more details see Chapter 2 RipEX2 HS in detail Note When t...

Page 17: ...Antenna There are different models in terms of antenna connectors see https www racom eu eng products ripex hot standby html order codes N female connector is always used Fig 3 9 N connector 17 RACOM...

Page 18: ...3 10 Power supply connector AC model Fig 3 11 Power supply connector DC model Power supply connector AC model 100 240 V AC equipped with T2 5A fuse Optionally 36 60 V DC 18 30 V DC or 10 30 V DC RipE...

Page 19: ...stallation 4 1 Mounting There are 3 variants of Mounting RipEX2 units Fig 4 1 RipEX2 HS Rack mounted 4 1 1 Mounting variant 1 Fig 4 2 RipEX2 HS RD RS rack tray shelf 19 RACOM s r o RipEX2 HS Installat...

Page 20: ...4 1 2 Mounting variant 2 Fig 4 3 RipEX2 HS RD RS L profile mount Note Screw holes placement depends on depth of the Rack RipEX2 HS RACOM s r o 20 Installation...

Page 21: ...hase would be off RipEX2 HS will still be On There are individual power connectors for each power supply See Section 3 3 Rear panel 4 2 2 36 60 V DC There are also two independent power supplies with...

Page 22: ...4 2 4 18 30 V DC There are also two independent power supplies with 18 to 30 V DC input voltage one for each RipEX2 unit input conductors are isolated from the rest of the RipEX HS and thus allows pos...

Page 23: ...g to the standby unit when an error status occur in active unit if both units are without alarms the A unit will be active Menu ADVANCED Device Unit menu Hot Standby Active HotStdby_Enable Listbox On...

Page 24: ...H5 active HotStdby_GuardETH_1_Enable HotStdby_GuardETH_5_Enable Listbox On OFF default Switches on guarding of the individual ETH link Note It is possible to change the active status from the A to the...

Page 25: ...1 The switch over works but the ETH connection starts working with some delay Check if MAC addresses are really identical for both active and inactive units 2 Automatic switch over does not take place...

Page 26: ...le separate Rx and Tx separate for each RipEX2 unit 4 N female A unit alarm B unit alarm HS controller alarm A and or B alarm HW inputs HW outputs Environmental IP40 IP Code Ingress Protection 900 000...

Page 27: ...r each RipEX2 unit standard RipEX2 LED panel 5 tri color LEDs SYS AUX RX TX COM 3 two color LEDs A AUTO B 1x ETH5 SFP LED panels Approvals RED RoHS WEEE CE 27 RACOM s r o RipEX2 HS Technical parameter...

Page 28: ...field region only Whenever the result is comparable or smaller than the ac tual size of the respective antenna the field intensity is even smaller than the far field based calculation and the safety l...

Page 29: ...cling and recovery of waste in an environmentally safe manner using processes that comply with the WEEE Directive Battery Disposal This product may contain a battery Batteries must be disposed of prop...

Page 30: ...lectrical and electronic equipment RoHS as amended by Directive EU 2015 863 and Directive 2012 19 EU of the European Parliament and of the Council on waste electrical and electronic equipment WEEE RoH...

Page 31: ...mum permitted output power RACOM is not responsible for products used in an unauthorised way Equipment mentioned in this operator manual may only be used in accordance with instructions contained in t...

Page 32: ...s Conditions of use of this product software abide by the license mentioned below The program spread by this license has been freed with the purpose to be useful but without any specific guarantee The...

Page 33: ...8 8 Product Conformity Fig 8 2 EU Declaration of Conformity RED 33 RACOM s r o RipEX2 HS Safety environment licensing...

Page 34: ...by prepaid freight If circumstances do not permit the equipment to be returned to RACOM then the customer is liable and agrees to reim burse RACOM for expenses incurred by RACOM during servicing the e...

Page 35: ...ublic License RTS Request To Send https Hypertext Transfer Protocol Secure RTU Remote Terminal Unit IP Internet Protocol RX Receiver kbps kilobit per second SCADA Supervisory control and data acquisit...

Page 36: ...working with While every reasonable effort has been made to ensure the accuracy of this publication product improvements may also result in minor differences between the manual and the product shippe...

Reviews: