background image

 

 

 

 

 

 

 

 

使

 

 

 

 

 

 

網路型數據機

 

T-336Cx/Nx/NDx 

 

 

 

Version: 1.6 

Date: 2006/8/10 

P/N: 07006-00014 

 

 

 

Headquarters: 

No. 25, Alley 15, Lane 120,  

S

EC

. 1. N

EI

-H

R

D

Taipei 114, Taiwan 

TEL: 886-2-26583000 

FAX: 886-2-26583232 

 

Beijing Branch: 

3F,  A Building,  

113 Zhi Chun Lu,  

HaiDian District,  

Beijing, China 

Zip Code: 100086 

TEL: 86-10-62522081~87 

FAX: 86-10-62522077

 

Summary of Contents for T-336C Series

Page 1: ...06 00014 Headquarters No 25 Alley 15 Lane 120 SEC 1 NEI HU RD Taipei 114 Taiwan TEL 886 2 26583000 FAX 886 2 26583232 Beijing Branch 3F A Building 113 Zhi Chun Lu HaiDian District Beijing China Zip Co...

Page 2: ......

Page 3: ...ation System Corporation Other product names mentioned in this manual are used for identification purposes only and may be trademarks or trademarks of their respective companies The information provid...

Page 4: ...ormation needed to install configure and operate TAINET s VENUS Series VoIP Gateway The summary of this manual is as follows Chapter 1 TAINET Modem Chapter 2 Chapter 3 Chapter 4 Chapter 5 Chapter 6 Ap...

Page 5: ...ed below Warning This symbol and associated text are used when death or injury to the user may result if operating instructions are not followed properly Note This symbol and associated text are used...

Page 6: ...h the written consent of TAINET THE ABOVE WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED THERE ARE NO WARRANTIES THAT EXTEND BEYOND THE FACE HEREOF INCLUDING BUT NOT LIMITED TO WARRA...

Page 7: ...T 336Cx Nx NDx v thereof in the Territory but TAINET makes NO WARRANTY EXPRESS OR IMPLIED WITH RESPECT THERETO...

Page 8: ...is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect...

Page 9: ...discontinue your service temporarily If possible they will notify you in advance But the advance notice isn t practical you will be notified as soon as possible You will be informed of your right to...

Page 10: ...TION 2 3 3 OPERATING THE TAINET NETWORK SERIES MODEM 3 3 4 THE MENU TREE 6 3 5 DETAILED DESCRIPTION OF THE MENU TREE 11 3 5 1 STATUS MENU 11 3 5 2 DIAL MENU 13 3 5 3 PROTOCOL MENU 14 3 5 4 TEST MENU 1...

Page 11: ...C PASSWORD CALLBACK 19 4 17 1 char 19 4 18 INTELLIGENT DIAL POLLING 20 5 1 5 1 AT AT COMMAND SET 1 5 2 AT 2 5 3 AT 3 5 4 DIAL MODIFIERS 5 5 5 AT RESULT CODE 6 5 6 V 25 BIS V 25BIS AUTO CALL UNIT 8 6 1...

Page 12: ......

Page 13: ...15200 300bps 33600 1200bps V 34 V 32bis V 32 V 34 33 6 kbps line probing symbol rate and carrier frequency selection V 34 Adaptive Precoding Non Linear Encoding Warping Constellation Expansion Multidi...

Page 14: ...1 TAINET MODEM 2 V 13 V 23 4 2...

Page 15: ...5 Extended overspeed range 2 3 to 2 5 33600 31200 28800 26400 24000 21600 19200 16800 14400 12000 960 0 7200 4800 2400 1200 bps 115200 76800 57600 38400 33600 32000 31200 28800 26400 24000 21 600 192...

Page 16: ...o 1024 V 32bis 14400T TCM 1800 2400 128 V 32bis 12000T TCM 1800 2400 64 V 329600 T TCM 1800 2400 32 V 329600 QAM 1800 2400 16 V 32bis 7200 T TCM 1800 2400 16 V 324800 QAM 1800 2400 4 V 26bis 2400 DPSK...

Page 17: ...oss 20 dB 300 3400 Hz Longitude Balance 60 dB 120 mA 50 220 25 110 mA ON 27 Vrms OFF 13 Vrms 16 50 Hz DTMF O P Lowband 8 1 dBm O P Highband 6 1 dBm Frequency Tolerance 1 TONE Duration and Spacing 95 m...

Page 18: ...tterns 511 90 265 VAC 47 63 Hz 36 72 VDC 0 C 50 C 25 C 70 C 95 W 180mm H 48mm D 262mm Weight 0 9kg W 220mm H 26mm D 328mm Weight 0 6kg W 19 H 6RU D 380mm Weight 8kg Weight 16kg EIA RS 232C CCITT V 24...

Page 19: ...12 VDC MODEM 15 114 TXC Transmit Clock MODEM 17 115 RXC Receive Clock MODEM 18 141 AL Local Analog Loopback DTE 20 108 DTR Data Terminal Ready DTE 21 140 RDL Remote Digital Loopback DTE 22 125 RING Ri...

Page 20: ...2 T 336Cx t V 34 33 6kbps modem T 336Nx t V 34 33 6kbps modem TRS16 T 336NDx t V 34 33 6kbps modem TRS32 NMC16 NMS TRS16 NMC32 NMS TRS32 TRS16 19 16 modem TRS32 19 32 modem PW 130AC 90 265 VAC 130W PW...

Page 21: ...2 1 2 2 1 Description MODEM TRS16 TRS32...

Page 22: ...2 2 2 2 Unpacking MODEM 2 Modular Telephone Cable RJ 45 8 Module Plug RJ 45 2 Modular Telephone Cable RJ 11 4 RJ 45 8 2 MODEM...

Page 23: ...2 3 2 3 Site Requirements F C C Electrical Surges F C C Article 250 of National Electrical Code Handbook Ground Rod 2 44 8 Surge Protector MODEM AC MODEM...

Page 24: ...2 4 2 4 Site Selection MODEM 10 15 6 1 83 MODEM TRS 16 NMC 16 TRS 32 NMC 32 TRS16 TRS32...

Page 25: ...2 5 2 5 AC Electrical Outlet Connection MODEM 90 265V AC 2A 4A DC Source Power Supply 36 72VDC...

Page 26: ...6 Connecting With Dial Line MODEM RJ 45 Leased Line RJ 11 DIAL LINE PHONE MODEM RJ 11 PHONE MODEM DIAL LINE MODEM phone RJ 11 PHONE 1 2 3 Tip 4 Ring 5 6 MODEM Dial Line RJ 11 Dial Line 1 2 3 Tip 4 Ri...

Page 27: ...2 7 ON OFF DTE PHONE LEASED DIAL RJ11 RJ11 RJ11 RJ11 2 1 Dial Line...

Page 28: ...2 8 2 7 Connecting With Leased Line MODEM LEASED LINE RJ 45 1 2 3 4 5 6 7 8 TX RX TX RX TX RX TX RX TX TX RX TX TX RX RX RX RJ 45 1 2 TX 7 8 RX RJ 11 4 5 TX RX 4 5 TX 3 6 RX A TX B RX A RX B TX...

Page 29: ...2 9 2 2 Leased Line...

Page 30: ......

Page 31: ...3 1 3 3 1 The Front Panel Description TAINET Modem 5 VO DA Key Right Key Left Key ENTER Key and EXIT Key 2 x 16 LCD 10 LED modem Figure 3 1 TAINET T 336Cx...

Page 32: ...3 2 3 2 The Rear Panel Description TAINET T 336Cx Modem IEC 320 AC RS 232 connector RJ11 RJ45 2W 4W Figure 3 2 TAINET T 336Cx...

Page 33: ...INET Network Series Modem VO DA voice data Modem Dial backup Menu HOME ENTER EXIT LED 10 PWR DTR DTR DSR DSR RTS RTS CTS CTS TXD 0 1 TXD DCD DCD RXD 0 1 RXD OH Off Hook TST LCD LCD 2x16 Example V34 33...

Page 34: ...shaking Connect Retrain Ring 9 8 7 6 0 Menu 1 2 L MENU Select STATUS L MENU Select TEST ENTER local remote L Local MENU ENTER MENU EXIT STATUS MENU Menu 1 2 L STATUS RX Level 10dBm R CONFIG MODEM TX c...

Page 35: ...3 5 1 2 LL TX Level 10dBm R Protocol type Auto MNP V42 ENTER EXIT...

Page 36: ...OMMAND LINE SETUP PROFILE LINE SETUP STATUS MENU REMOTE STATUS MENU Tx Level XX dBm Rx Level XX dBm S N Ratio XX dB EQM Valueio XXX F Shift X X Hz F F Shift X X Hz Delay XXXX ms P jitter X Deg STATUS...

Page 37: ...Dial Busy Tone Redial Delay Immediate 1 255 Second Dial Type Tone Pulse SPK Control Until DCD on Always on Off when dial Off SPK Volume Low Medium High PROTOCOL MENU Protocol Type Normal Direct Relian...

Page 38: ...V32b 144 V32b 120 V32 96Q V32 96T V32b 72 V32 48 V26b 24 V26b 12 V23 1200 V22b 2400 V22 1200 BELL 212A BELL 103 V21 300 ORG ANS Mode Answer Mode Originate Mode Auto Retrain On Off Tx Clock Internal E...

Page 39: ...TS Control Force On Normal DSR Control Normal Force On DCD Control Force On Normal V 13 HDX V 23 HDX Data Format ASYNC SYNC Total Bits 8 9 10 11 AL by 141 Off On RDL by 140 Off On G COMMAND MENU Comma...

Page 40: ...Leased Timer Forver 0 255 Minutes Dial to Dail Off On I PROFILE MENU Load User Profiles 0 9 0 AS DL AT AUTO 1 AS DL AT NONE 2 SY DL V25 NONE 3 AS 2L ANS V34 4 AS 2L ORG V34 5 SY 2L ANS V34 6 SY 2L OR...

Page 41: ...10 13 dBm S N V 34 TX level 13dBm RX LEVEL XX dBm AT S 15 33 dBm S N RATIO XX dB AT S S N 14400 bps 24 dB 9600 bps 20dB 28800 bps 33dB EQM VALUE XXX AT S Eye pattern F SHIFT XX Hz AT S 7 Hz F F SHIFT...

Page 42: ...U RETRAIN ATO2 Modem RX BAUD XXXX AT S V 34 TX BAUD XXXX AT S V 34 RX FREQ XXXXHz AT S V 34 TX FREQ XXXXHz AT S V 34 TX SPEED XXXXbps AT S Modem RX SPEED XXXXbps AT S Modem TX POWEROFF XdB AT S TX pow...

Page 43: ...x 1 xxx Ring Times ATS0 n 1 108 1 DTR ON Auto Dial Ans Off DTE DTR Auto Ans Off ATS0 0 1 255 Times 1 255 Progress Tone ATXn Basic ATX0 Don t Care ATX1 Dial Tone ATX2 Busy Tone ATX3 Dial Busy Tone ATX4...

Page 44: ...DTE Data Flow Control Direct AT N1 V42 MNP Reliant MNP AT N2 MNP Auto AT N3 V42 MNP V42bis V42 MNP5 MNP4 Normal Reliant LAPM AT N4 V42 LAPM Normal AT N5 V42 V42bis V42 Normal LAPM MNP AT N6 V42 MNP V...

Page 45: ...ANS 0 9 0 9 4 17 ALL 0 9 ANS 0 9 4 17 By NMS ANS T 336Nx NDx CS V1 5x ANS standalone model T 336Cx ALL CS V1 5x CS server Send Password ORG Off Dynamic Password 0 9 0 9 0 9 4 17 CallBack No 0 9 0 9 Ca...

Page 46: ...5 4 TEST MENU Clear All AT T0 Has been done LAL ON OFF AT T1 ON OFF B E R Test RDL ON OFF AT T6 ON OFF B E R Test DL ON OFF AT T3 ON OFF RDL Grant RDL ON AT T4 OFF AT T5 Error Count 0 65535 ENTER 0 B...

Page 47: ...V34 96 AT B33 V34 9600 bps 4DTCM SM V34 72 AT B32 V34 7200 bps 4DTCM SM V34 48 AT B31 V34 4800 bps 4DTCM SM V34 24 AT B40 V34 2400 bps 4DTCM SM V32b Adapt AT B47 V 32 V 32b V 32 V 22bis V 22 V 21 V32b...

Page 48: ...f AT E0 Retrain Tx Clock AT Xn Internal AT X0 External AT X1 Loopback AT X2 Polling Slave LL TX Level ATS30 n 0 31 dBm 13dBm DL TX Level ATS56 n 0 15 dBm 13dBm ASI Overspeed AT An ITU T V 14 1 AT A0 1...

Page 49: ...FB FF CTRL AT Gn S N On AT G1 Off AT G2 Remote Access ATS27 n bit3 Secondary channel Modem On Off Dynamic Range ATS28 n bit0 12 44dBm 12 44 dBm 2 35 dBm 2 35 dBm 3 5 6 CONFIG DTE MENU DTE Speed 300 bp...

Page 50: ...s AT ON 57600bps Flow Control AT Qn V42 MNP Off AT Q0 X ON X OFF AT Q1 TEXT CTS Only AT Q2 RTS CTS RTS RTS CTS AT Q3 DTR CTL AT Dn DTR OFF ON 108 2 AT D0 V 25 108 2 DTR operation 108 1 AT D1 V 25 V 25...

Page 51: ...ormal AT C1 DCD ON DCD off V 13 HDX AT C2 ITU T V 13 V 23 HDX AT C2 ITU T V 23 RTS Control AT Rn RTS Normal AT R0 Forced on AT R1 ON RTS Data Format AT Mn Data Async AT M0 Sync AT M1 Total bits ATS19...

Page 52: ...ISYN MONOSYN HDLC SDLC Dumb mode Auto Baud AT Un AT On AT U1 Off AT U0 Framing ATS19 n V 25bis ASYNC bit1 0 HDLC SDLC HDLC SDLC BSC Bisync monosync Async form ATS19 n bit5 4 7 O 1 7bits 1 7 E 1 7bits...

Page 53: ...ATS31 n Manual bit0 Auto Backup Tel No dial backup 0 nnnn to 9 nnnn 0 9 0 9 Backup Speed ATS55 n V34 Adapt to V21 300 V 34 288 Dial To Leased ATS31 n Manual bit1 Auto D to L Timer ATS36 n Forever 1 2...

Page 54: ...V 25bis IBM 3 AS 2L ANS V34 AT F3 W V 34 288 4 AS 2L ORG V34 AT F4 W V 34 288 Originate 5 SY 2L ANS V34 AT F5 W V 34 288 6 SY 2L ORG V34 AT F6 W V 34 288 Originate 7 SY 4L ANS V34 AT F7 W V 34 288 8...

Page 55: ...L R ENTER E EXIT X VO DA V Input _ _ _ _ R E E E ENTER ENTER ENTER Power up AT Yn User Profile 0 9 Initial AT F1 0 Are you sure Enter Serg edit ATSn m S Base DEC S Base Bin S Enter XX XX Enter S Ente...

Page 56: ......

Page 57: ...4 1 4 4 1 PREVIEW...

Page 58: ...ne VS Leased Line 24 Path DTE MODEM MODEM DTE FIG 4 1 Leased Line BBS 080 45 60 LINE SETUP MENU Line Type Dial Line 2W Leased Line 4W Leased Line DTE MODEM DTE MODEM MODEM MODEM DTE DTE PSDN A B C D F...

Page 59: ...4 3 4 3 2W 4W Leased Line Leased Line Full Duplex V 21 V 22 V 22Bis V 32 V32bis V 34 Echo Cancellation DTE MODEM DTE MODEM MODEM MODEM DTE DTE 2W Leased Line 4W Leased Line FIG 4 3...

Page 60: ...ginate mode VS Answer mode Originate Answer ORG ANS Training Sequence Protocol V 21 V 22 V 22bis V 23 V 32 V 32bis V 34 BELL 103 BELL 212A Originate Answer CONFIG MODEM MENU ORG ANS MODE AT command MO...

Page 61: ...4 5 4 5 Synchronous VS Asynchronous MODEM Data Format Synchronous Asynchronous IBM HOST MODEM V 21 V 23 BELL 103 CONFIG DTE MENU Data Format Async Data Bits DTE Speed AT command MODEM...

Page 62: ...oughput 2 4 Throughput DTE Speed 115200 bps MNP 4 5 MNP 4 MNP 5 ITU T V 42 V 42bis V 42 V 42bis MODEM MNP V 42 V 42bis EC LAPM MNP 5 MNP 4 NORMAL Flow Control Flow Control Hardware RTS CTS CTS X ON X...

Page 63: ...V34 SYN 2L ANS V34 SYN 2L ORG V34 SYN 4L ANS V34 SYN 4L ORG V34 ASY 2L ANS Auto DATA FORMAT ASYNC ASYNC SYNC ASYN C ASYN C SYNC SYNC SYNC SYNC ASYN C COMMA ND AT AT V25bis DUMB DUMB DUMB DUMB DUMB DU...

Page 64: ...Off Off Off Off Off Off RTS C TS RTS CTRL ON ON Normal ON ON Normal Normal Normal Normal Normal DCD CTRL Normal ON Normal Normal Normal Normal Normal Normal Normal Normal DTR OFF ON ON DISCN T ON ON...

Page 65: ...4 9 4 8 Remote Access Sec channel Remote Access ON CONFIG MODEM MENU LOCAL LCD LOCAL REMOTE LOCAL ENTER...

Page 66: ...4 10 4 9 Multi standard Handshake T 336Cx Nx NDx Modem V 34 V 32bis V 32 V 22bis V 21 V 8 V 42 and V 42bis Modem Adaptive Modem...

Page 67: ...uto Dial Backup PROTOCOL DIAL LINE MODEM LINK MODEM LINE SETUP MENU Leased To Dial Dial To Leased AUTO MANUAL ORG Backup Tel Back Up DIAL MENU PROTOCOL LINK LINE SETUP MENU Dial To Dial ON DIAL MENU R...

Page 68: ...4 12 4 11 Auto Fallback And Fall Forward Modem FB FF Ctrl ON Auto Retrain On retrain threshold S N threshold V 34 V 32 Modem Modem Speed CONFIG MODEM MENU...

Page 69: ...splay 0 9 B E R 9 10 9 8 10 8 7 10 7 6 10 6 5 10 5 4 10 4 3 10 3 2 10 2 1 10 1 0 NO Connect 10 5 10 6 1 Tx level 10 dBm 2 Rx level 25 dBm 3 S N Ratio 35 dB 4 F Shift 0 2 Hz 5 F F Shift 1 7 Hz 6 Delay...

Page 70: ...4 14 10 Retrains 1 STATUS MENU Remote Access REMOTE STATUS MENU ON B E R Test...

Page 71: ...4 15 4 13 B E R Test TEST MENU B E R Test ON Error Count Burst type ENTER Error Count 0 511 Test MENU TP Type RDL Test MENU RDL AL MODEM 0...

Page 72: ...4 16 4 14 Intelligent Dial Multiplexer Controller AT LCD 10 108 1 DTR Off ON...

Page 73: ...4 17 4 15 Front Panel Lock Password PROFILE MENU Front Lock Lock Save Unlock Password EXIT X ENTER E VO DA V R L REEE...

Page 74: ...4 18 4 16 ITU T V 13 V 23 Simulated Carrier In Half Duplex Mode Modem Polling V 13 V 23 CONFIG DTE MENU DCD Control V 13 V 23 Modem RTS DCD RTS...

Page 75: ...word CallBack AT string string ANS Send Password Send Password Off string string ANS ANS ORG string ORG Call Back no ORG Send Password Off Call Back No Disable string 4 17 1 char char char char ATDT12...

Page 76: ...Number 0 9 Originate VO DA key Idle Telephone Number Tel 0 12345678 Tel 1 23456789 Tel 2 34567890 User 0 1 2 2 User Dial to Dial On 2 User ATDTxxxx Telephone Number 0 DTR off to on 108 1 0 Dial to Dia...

Page 77: ...Checksum 2 Verify ROM checksum 3 Report ROM components 4 Modem capabilities and version 5 Country Code 6 Pump controller CS 7 Pump DSP CS 8 CTL SPX Version 9 OK ATLn 0 1 2 ATMn 0 1 DCD 2 3 HANDSHAKIN...

Page 78: ...OFF 2 DTR OFF 3 DTR OFF MODEM AT Fn factory default n n 0 9 AT Gn 0 1 550Hz 2 1800Hz AT Knor AT Qn DTE flow control 0 none 1 XON XOFF 2 RTS CTS 3 CTS AT Ln 0 1 2 AT Mnor AT Qn Direct 0 Async 1 Sync AT...

Page 79: ...ble mode 4 LAPM reliable 5 LAPM reliable with fallback to Normal mode 6 LAPM reliable with fallback to MNP mode 7 MNP reliable with fallback to Normal mode AT An 0 1 to 2 5 1 2 3 to 2 5 AT Bn MODEM 0...

Page 80: ..._16800 36 V34_21600 37 V34_26400 38 V34_12000 40 V34_2400 41 V34_31200 42 V34_33600 43 V17_7200 44 V17_9600 45 V17_12000 46 V17_14400 47 V32b_Adaptive AT Cn 0 off 1 on AT Dn DTR 0 normal 108 2 1 DTR o...

Page 81: ...4 Dial Modifiers Table 5 2 Dial Modifiers for AT and V 25bis command CODE Function Description T or t DTMF dial P or p Pulse dial 0 to 9 A to D a to d FLASH W or w or or R or r Answer mode Sn or sn or...

Page 82: ...O CARRIER 4 ERROR 5 CONNECT 1200 6 NO DIAL TONE 7 BUSY 8 NO ANSWER TONE 10 CONNECT 300 11 CONNECT 600 13 CONNECT 1800 14 CONNECT 2400 15 CONNECT 3600 16 CONNECT 4800 17 CONNECT 7200 18 CONNECT 9600 19...

Page 83: ...7 Table 5 3 Result Codes cont 24 CONNECT 24000 25 CONNECT 26400 26 CONNECT 28800 27 CONNECT 32000 28 CONNECT 38400 29 CONNECT 57600 30 CONNECT 76800 31 CONNECT 115200 32 CONNECT 31200 33 CONNECT 3360...

Page 84: ...0 y x RLN CIC CALL CIC CR MODEM DIC MODEM 3 RESPONCES INC MODEM INC DTE INV MODEM INV DTE VAL MODEM VAL DTE LSN MODEM RLN LSNn 0 9 CNX DATA MODE 4 CALL FAILURE RESPONSES CFIET BUSY TONE CFIAB MODEM AB...

Page 85: ...6 1 6 6 1 Description...

Page 86: ...6 2 6 2 Instruments...

Page 87: ...6 3 6 3 Periodic Manintenance A B...

Page 88: ...6 4 6 4 Troubleshooting LED LCD OFF IC ON 1 A AC 110V 60Hz 220V 50Hz B 2A 4A 2 RS 232C A AL B LED...

Page 89: ...6 5 6 5 Return Procedure 02 2658 3000 10 6444 9830 1...

Page 90: ......

Page 91: ...lind Dial S7 45 second Wait for Carrier Time S8 2 second Pause for Comma S9 6 100ms Carrier Validation Time S10 15 1 1s Lost Carrier Detect Time 1 sec unit for V34 V32bis V32 0 1 sec unit for V22bis V...

Page 92: ...sponse on 1 ATQ1 response off bit 3 0 ATV0 response code 1 ATV1 response word bit 4 reserved bit 5 0 ATT Tone Dial 1 ATP Pulse Dial No Default Unit Function Description bit 6 reserved bit 7 0 ATA Answ...

Page 93: ...data no parity 1 stop bit 10 7 bit data odd parity 1 stop bit 11 7 bit data no parity 2 stop bit bit 6 DTR off cause busy out nothing bit 7 0 V 32bis fast training disable 1 V 32bis fast training enab...

Page 94: ...ed 010 reserved 011 reserved 100 ATX1 CONNECT with speed message blind dial no busy tone Dialn Tone 101 ATX2 CONNECT with speed message wait for dial tone no busy tone 110 ATX3 CONNECT with speed mess...

Page 95: ...ions bit 1 0 DTR off to on control 00 AT D0 normal 108 2 01 AT D1 dial ans according to ring in 108 1 10 reserved 11 reserved bit 3 2 reserved bit 7 4 Login check 0000 1001 0 9 1010 ALL 1011 By NMS 11...

Page 96: ...ons bit 0 1 2 to 35 dBm receive dynamic range 0 12 to 44 dBm receive dynamic range bit 1 reserved bit 3 2 disconnect option 00 send clear down before disconnect 01 immediately disconnect 10 reset mode...

Page 97: ...dial 0 manual 1 auto bit 1 dial to leased 0 manual 1 auto bit 2 V 32 auto FFFB by Retrain bit 3 reserved bit 7 6 5 4 backup tel 0 9 no dial backup S32 0 reserved S33 Test time minute S34 Test time sec...

Page 98: ...n S42 00000010 binary Bit Mapped Options bit 0 0 far echo canceler off 1 far echo canceler on bit 1 0 receive power drop control off 1 receive power drop control on bit 2 0 enable V 34 asymmetrical ra...

Page 99: ...CTS only flow control 11 AT Q3 AT K3 RTS CTS flow control No Default Unit Function Description bit 3 2 DTE DCE speed convert 00 AT J0 enable DTE DCE speed convert 01 AT J1 disable DTE DCE speed conver...

Page 100: ...ved 46 reserved 47 V32b_Adaptive S53 00010011 binary Bit Mapped Options bit 3 2 1 0 protocol type 0000 AT N0 normal mode 0010 AT N2 MNP reliable mode 0011 AT N3 auto reliable mode 0100 AT N4 LAPM reli...

Page 101: ...Call back telephone number 0000 1001 0 9 S55 backup speed V 34 33600 V 21 300 S56 13 dBm Dial Line Tx Level S57 00 binary Bit Mapped Options bit 1 0 retrain threshold 0 0 High 01 medium 10 Low 11 rese...

Page 102: ......

Page 103: ...Check DL Auto Retrain DTR Off Action Framing Backup Tel Initial EQM Progress Tone Send password RDL Tx Clock DTR Control Async form Backup Speed Front Lock T F Shift Redial Delay Call Back No RDL Gra...

Page 104: ...Appendix C T 336Nx LCD Menu Quick Reference 64 TX Baud Remote Access RX Freq Dynamic Range TX Freq RX Speed TX Speed Tx Power Off Interface indicators...

Page 105: ...Appendix C T 336Nx LCD Menu Quick Reference 65 Appendix C T 336Nx LCD Menu Quick Reference...

Page 106: ...Dial Backup Card Fail 01Select Menu Ararm Config 01 Alarm Config Group Setup 01 Group Setup XXXXXXXXXXXXXXXX RXL Low RXL High SNR Bad Chk Dial Line Dial Backup DTR Off TD RD Inactive N Echo High 01 Se...