background image

 

UniMod Ethernet

 

LAN-Modem

 

Operation Manual 

E121712216066 

 

Bär Industrie-Elektronik GmbH 

Siemensstr. 3 

D-90766 Fürth 

Germany 

 

Phone: +49 (0)911 970590 

Fax: +49 (0)911 9705950 

Internet: 

www.baer-gmbh.com

 

 

Summary of Contents for UniMod Ethernet

Page 1: ...UniMod Ethernet LAN Modem Operation Manual E121712216066 B r Industrie Elektronik GmbH Siemensstr 3 D 90766 F rth Germany Phone 49 0 911 970590 Fax 49 0 911 9705950 Internet www baer gmbh com...

Page 2: ...GmbH pre serve the right to modify and improve the software product described in this document Specifica tions and other information contained in this document can change without prior notice This doc...

Page 3: ...al 5 2 Power Supply Unit 5 3 Interfaces 5 4 Display 5 5 Installation Hints 5 6 Programming the Modem 6 7 Reset Function 11 8 Inserting the Interface Modules 12 9 Technical Data 13 10 Terminal Block 14...

Page 4: ...UniMod Ethernet 4...

Page 5: ...ies current or passive RS232 interface module uses signals RxD TxD CTS RTS GND DTR DCD DSR RS485 interface module M Bus interface module active can supply 20 devices max 10 old version Communication i...

Page 6: ...TCP IP Line check PORT 1234 Standard port number 1234 This configuration allows for reading meters of type VDEW IEC1107 IEC62056 21 If you want to change this parameters a PC with terminal software e...

Page 7: ...2 Set the switch to left position 01L as shown in the picture Position 01L GSM 3 Insert the 7 pole plug of the parametering adapter instead of the interface module The notch must point upwards 4 Then...

Page 8: ...dress and port number Gateway Subnet Mask Data transmit control Keep alive For the network parameters ask your system administrator Then select in the menu Settings Interface the serial port e g COM1...

Page 9: ...ERNET OK Requests product information since 2007 ETHERNET V3 at f OK Set all parameters to factory defaults ats0 n OK This parameter setting determines the number of rings 0 to 255 before automatic an...

Page 10: ...eters Save current parameters Enter AT W No answer if ATQ1 command has been issued be fore Parameterization finished Dial The modem picks up and dials in accordance with the dialing string given by th...

Page 11: ...ifier must be entered The command ATZ resets the modem Starting with version ETHERNET V3 can be queried using ATI command access must be ena bled by entering username and password Default values are i...

Page 12: ...e interface modules their component side must be at the left side and wired ac cording the picture In the following sketch the components are at the left side RS232 20mA active 20mA pas RS485 M Bus ac...

Page 13: ...max Display LED s for signals operation Rst Hook DCD TxD and RxD Transmission rate remote modem to UniMod 10 Mbits s IEEE802 3 Ethernet connection 10 Base T Protocols ARP ICMP TCP IP UDP IP Transmissi...

Page 14: ...Block 11 Ethernet Interface Ethernet Standard configuration RJ45 11 TX RJ45 pin 2 colour red 12 RX RJ45 pin 6 colour green 13 TX RJ45 pin 1 colour red white 14 RX RJ45 pin 3 colour green white Note C...

Page 15: ...UniMod Ethernet 15 12 Dimensions Wall mounted housing DIN 43861 2...

Page 16: ...UniMod Ethernet 16...

Reviews: