End IP
DHCP server assigns IP addresses to clients from the range defined by Start IP and End IP (inclus-
ive).
•
No of leases
Default = 5 [1 - 255]
Maximum number of DHCP client(s) which can RipEX simultaneously serve. It can not be more
than the number of addresses available in the Start IP - End IP range.
•
Lease timeout [DD:HH:MM:SS]
Default = 1 day (max. 10 days)
A DHCP Client has to ask DHCP Server for refresh of the received configuration within this timeout,
otherwise the Lease expires and the same settings can be assigned to another device (MAC).
•
Assigned IP's
Table shows MAC addresses of Clients and IP addresses assigned to them by the Server. Expiration
is the remaining time till the respective Lease expires. If the assigned IP addresses are required to
be deleted, set DHCP Server to Off, then action Apply and set DHCP server to On (+Apply) again.
•
Preferred IP's
It is possible to define which IP should be assigned by the Server to a specific MAC. The requested
IP has to be within the Start IP – End IP range.
Shaping*
List box: On, Off
Default = Off
Ethernet interface could easily overload the Radio channel. Because of that, it is possible to shape
traffic received from the ETH interface.
If
On
, specified volume of
Data [Bytes]
in specified
Period [s]
is allowed to enter the RipEX from ETH
interface. The first packet which exceeds the limit is stored in the buffer and transmitted when new
Period starts. Further over-limit packets are discarded.
Speed
List box: Auto, 100baseTX/Full, 100baseTX/Half, 10baseT/Full, 10baseT/Half
Default = Auto
Communication speed on the Ethernet interface.
Modbus TCP*
Use this setttings only for
Modbus TCP Master
when it communicates with both types of Modbus
slaves using either Modbus RTU or Modbus TCP protocols. Or when TCP/IP communication should
run locally between Modbus Master and RipEX in Modbus TCP network. Read Help and Application
note Modbus in RipEX.
For more information refer to the manual Application note / Modbus TCP
.
** - denotes items to be used only when either all or some RTUs (Remote Telemetry Unit) on remote
sites are connected via RS232 or RS485 interface to RipEX, using the Modus RTU protocol. Then
automatic conversion between Modbus TCP and Modbus RTU protocols takes place for such units.
List box: On, Off
Default = Off
1
http://www.racom.eu/eng/products/m/ripex/app/modbus.html
RipEX Radio modem & Router – © RACOM s.r.o.
110
Advanced Configuration
Summary of Contents for RipEX 1.12.0
Page 2: ......
Page 172: ...RipEX Radio modem Router RACOM s r o 172 Safety environment licensing...
Page 173: ...173 RACOM s r o RipEX Radio modem Router Safety environment licensing...
Page 175: ...175 RACOM s r o RipEX Radio modem Router Safety environment licensing...
Page 176: ...RipEX Radio modem Router RACOM s r o 176 Safety environment licensing...
Page 186: ...186...
Page 187: ...Appendix C Revision History 187 RACOM s r o RipEX Radio modem Router Revision History...