- 81 -
8.2 Other Malfunctions and Solutions (No display on LED wire controller)
Malfunctions
Observing
Reasons
Solution
Heat pump is
not running
LED wire controller
no display.
No power supply
Check cable and circuit breaker
if it is connected
LED wire controller.
Displays the actual time.
Heat pump under standby
status
Startup heat pump to run.
LED wire controller
displays the actual
water temperature.
1. Water temperature is
reaching to setting value, HP
under constant temperature
status.
2. Heat pump just starts to run.
3. Under defrosting.
1. Verify water temperature
setting.
2. Startup heat pump after a
few minutes.
3. LED wire controller should
display "Defrosting".
Water temperature is
cooling when HP
runs under heating
mode
LED wire controller displays
actual water temperature and
no error code displays.
1. Choose the wrong mode.
2. Figures show defects.
3. Controller defect.
1. Adjust the mode to proper
running
2. Replace the defect LED wire
controller, and then check the
status after changing the
running mode, verifying the
water inlet and outlet
temperature.
3. Replace or repair the heat
pump unit
Short running
LED displays actual water
temperature, no error code
displays.
1. Fan NO running.
2. Air ventilation is not enough.
3. Refrigerant is not enough.
1. Check the cable connections
between the motor and fan, if
necessary, it should be
replaced.
2. Check the location of heat
pump unit, and eliminate all
obstacles to make good air
ventilation.
3 Replace or repair the heat
pump unit.
water stains
Water stains on heat pump
unit.
1. Concreting.
2. Water leakage.
1. No action.
2. Check the titanium heat
exchanger carefully if it is any
defect.
Too much ice on
evaporator
Too much ice on evaporator.
1. Check the location of heat
pump unit, and eliminate all
obstacles to make good air
ventilation.
2. Replace or repair the heat
pump unit.
Summary of Contents for INVERTER 11
Page 1: ...POMPE CHALEUR DE PISCINE D RACER INVERTER NOTICE D INSTALLATION ET D UTILISATION...
Page 2: ......
Page 6: ...3 2 Dimension 2 1 Dimension Mod les RACER INVERTER 7 9 KW...
Page 7: ...4 Mod les RACER INVERTER 11 14 16 KW Mod les RACER INVERTER 19 KW 25KW...
Page 42: ...39 10 Sch ma clat et liste des pi ces d tach es 10 1 Mod le RACER INVERTER 7KW 9KW...
Page 45: ...42 10 2 Mod le RACER INVERTER 11KW 14KW 16KW...
Page 49: ...46 10 3 Mod le RACER INVERTER 19KW 25KW...
Page 53: ...50 Swimming Pool Heat Pump RACER INVERTER...
Page 57: ...54 2 Dimension 2 1 Dimension RACER INVERTER 7 9 KW...
Page 58: ...55 RACER INVERTER 11 14 16 KW RACER INVERTER 19 KW 25 KW...
Page 87: ...84 2 3 The main interface...
Page 93: ...90 10 Exploded Diagram and spares parts list 10 1 RACER INVERTER 7KW 9KW...
Page 96: ...93 10 2 RACER INVERTER 11KW 14KW 16KW...
Page 100: ...97 10 3 RACER INVERTER 19KW 25KW...
Page 104: ......
Page 105: ......
Page 106: ......
Page 107: ......
Page 108: ...CASH PISCINES FRANCE 13 Avenue Neil Armstrong 33700 M rignac A0165RCI02...