background image

26
26

ENGLISH 

Cautions 

Please  read  the  warning  notices  given  in  this  section  very carefully,  because  they  provide  important  information 

regarding safety in installation, use and maintenance of the pump. 

Keep this manual in a safe place, so that it will always be 

available for further consultation. 

The pump complies with EEC directives No.89/336 regarding "electromagnetic compatibility" and No.73/23 regarding 

"low voltages", as also the subsequent modification No.93/68. 

The pump has been constructed in accordance with best practice. Both its life and it electrical and mechanical reliability will be 

enhanced if it is correctly used and subjected to regular maintenance. 

WARNING:  Any  intervention  or  repair  to  the  internal  parts  of  the  pump  must  be  carried  out  by  qualified  and  authorized 

personnel. The manufacturers decline all responsibility for the consequences of failure to respect this rule. 

GUARANTEE: 2 years (the normal wearing parts are excluded, i.e.: valves, nipples, tube nuts, tubing, filter and injection valve). 

Improper use of the equipment invalidates the above guarantee. The guarantee is exfactory or authorized distributors. 

 Shipping  and transporting  the pump 

The pump should always be moved in a vertical (and never in a horizontal) position. No matter what the means of transport 

employed, delivery of the pump, even when free to the purchaser's or the addressee's domicile, is always at the purchaser's risk. 

Claims for any missing materials must be made within 10 (ten) days of arrival, while claims for defective materials will be considered 
up to the 30th (thirtieth) day following receipt. Return of pumps or other materials to us or the authorized distributor must be agreed 
beforehand with the responsible personnel. 

 Proper use o f  the pump 

The pump should be used only for the purpose for which it has been expressly designed, namely the dosing of liquid additives. 

Any different use is to be considered improper and therefore dangerous.The pump should not therefore be used for applications 
that were not allowed for in its design. In case of doubt, please contact our offices for further information about the characteristics 

of the pump and its proper use. The manufactures cannot be held responsible for damage deriving from improper, erroneous or 
unreasonable use of the pump. 

 Risks 

After unpacking the pump, make sure it is completely sound. In case of doubt, do not use the pump and contact qualified 

personnel. The packing materials (especially bags made of plastics, polystyrene, etc.) should be kept out of the reach of children: 
they constitute potential sources of danger. 

Before you connect the pump, make sure that the voltage ratings, etc., correspond to your particular power supply. You will 

find these values on the rating plate attached to the pump. 

The electrical installation to which the pump is connected must comply with the standards and good practice rule  in force  in 

the country under consideration. 

 

Use of electrical equipment always implies observance of some basic rules: In particular:

do not touch the equipment with wet or damp hands or feet;

do not operate the pump with bare feet (Example: swimming pool  equipment);

do not leave the equipment exposed to the action of the atmospheric agents;

do not allow the pump to be used by children or unskilled individuals without supervision;

In case of breakdown or improper functioning of the pump, switch off, but do not touch. Contact our technical assistance for 

any necessary repairs and insist on the use of original spares. Failure to respect this condition could render the pump unsafe for 
use. 

When you decide to make no further use of an installed pump, make sure to disconnect it from the power supply. 

HINTS AND WARNINGS 

Summary of Contents for COMPACT C-11-216294

Page 1: ...NOTICE D UTILISATION INSTRUCTIONS FOR USE INSTRUCCIONES DE USO R GULATEUR DE pH pH REGULATOR REGULADOR DEL pH...

Page 2: ......

Page 3: ...nvoyons pour les d tails et les approfondissements ult rieurs pr voit des sanctions pour la mise en d charge abusive desdits rebus ES DIRECTIVA RAEE ACTUALIZADO A LA LTIMA EDICI N SOBRE RESIDUOS DE AP...

Page 4: ......

Page 5: ...POMPE P RISTALTIQUE S RIE RACER COMPACT 9 Principe de fonctionnement des pompes p ristaltiques 9 Caract ristiques principales 9 Caract ristiques techniques 9 Mat riaux en contact avec l additif 9 INST...

Page 6: ...reils utilis s la piscine ne pas laisser l appareil expos aux agents atmosph riques pluie soleil etc ne pas permettre que la pompe soit utilis e entretenue ou nettoy e par des enfants ou par des perso...

Page 7: ...t le retour des flux vers la source comme par exemple des clapets anti retour etc ATTENTION Prot gez la pompe et les produits chimiques des l ments gel pluie soleil etc Il est recommand d installer la...

Page 8: ...e tout le liquide pr sent en d montant et en remontant le corps de pompe en utilisant les quatre vis de fixation couple de serrage 180 200 N cm Pour ce dernier point une attention particuli re est exi...

Page 9: ...es principales Appareils produits conform ment la norme CE Mat riau du bo tier Polypropyl ne Alimentation lectrique standard les fluctuations maximales autoris es sont de 10 230 V 50 60 Hz monophas e...

Page 10: ...n et le fixer avec l crou anneau La vanne d injection est galement un clapet anti retour RACER COMPACT PH RX Caract ristiques du RACER COMPACT Le RACER COMPACT est un produit facile utiliser compos d...

Page 11: ...alt ration de la solution tampon Le RACER COMPACT effectue tout de m me la proc dure d talonnage mais l affichage clignotant indique un d faut teindre et rallumer RACER COMPACT pour interrompre le mes...

Page 12: ...quel r actif utiliser car cela d pend de l additif utilis Ceci dit nous pouvons vous conseiller la mani re d intervenir si la pompe travaille avec de l hypochlorite de sodium cas le plus fr quent 1 S...

Page 13: ......

Page 14: ......

Page 15: ...BOMBA PERIST LTICA SERIE RACER COMPACT 19 Principio de funcionamiento de las bombas perist lticas 19 Caracter sticas principales 19 Caracter sticas t cnicas 19 Materiales en contacto con el aditivo 19...

Page 16: ...scalzo situaci n t pica aparatos utilizados en piscinas no deje el aparato expuesto a los agentes atmosf ricos lluvia sol etc no permita que la bomba sea utilizada mantenida o limpiada por ni os o per...

Page 17: ...e impidan el retorno de los flujos hacia la fuente como por ejemplo v lvulas de control etc ADVERTENCIA Proteja la bomba y las sustancias qu micas de los elementos escarcha lluvia sol etc Se recomiend...

Page 18: ...resente del cuerpo de la bomba desmontando y volviendo a montar el cuerpo de la bomba utilizando los cuatro tornillos de fijaci n con un par de apriete de 180 200 N cm Para este ltimo punto hay que pr...

Page 19: ...uipos fabricados en conformidad con la norma CE Caja de material Polipropileno Alimentaci n el ctrica est ndar se permiten fluctuaciones m ximas del 10 230 V ca 50 60 Hz monof sica Fig 1 Vistas y dime...

Page 20: ...MPACT PH RX Caracter sticas del RACER COMPACT El RACER COMPACT es un producto de uso f cil compuesto por una bomba perist ltica u por unos componentes electr nicos capaces de medir y regular los valor...

Page 21: ...H Introduzca la sonda en la soluci n tamp n a 650 mV en la pantalla aparece la medida detectada una vez estabilizada la medici n solo parpadea el mensaje mV Confirme el valor con CAL El RACER COMPACT...

Page 22: ...o de sodio caso m s frecuente 1 aseg rese de que la misma est apagada 2 desconecte el tubo de impulsi n de la instalaci n 3 quite el tubo de aspiraci n con filtro del dep sito y sum rjalo en agua limp...

Page 23: ......

Page 24: ......

Page 25: ...t 27 Operating principle 27 Common features 28 Liquid ends materials 28 Features of RACER COMPACT 30 Controls 30 Priming 30 Setpoint setting 30 Calibration 30 Configuration and Reset procedure 31 Mech...

Page 26: ...mp The pump should be used only for the purpose for which it has been expressly designed namely the dosing of liquid additives Any different use is to be considered improper and therefore dangerous Th...

Page 27: ...which shows all the pump details and a complete overview of all the pump components These drawings are in any case quite indispensable whenever defective parts have to be re ordered For the same purpo...

Page 28: ...ower supply fluctuations not to exceed 10 230 V a c 50 Hz single phase Model Max Flow Rate l h Max Pressure bar Weight Kg Consumption W Speed rpm Tube mm Compact 1 5 1 5 1 15 20 4 x 7 Liquid ends mate...

Page 29: ...um distance of 3 mm between the contacts Before accessing any of the electrical parts make sure that all the supply circuits are open Fig 2 Installation and terminals You can connect auxiliary inputs...

Page 30: ...valve and fix it with the supplied tube nut The injection valve also acts as no return valve by means of a cylinder sleeve Features of e Pool RACER COMPACT is a user friendly equipment made with a pe...

Page 31: ...side the 650 mV buffer solution The display shows the measure when the measure is stabilized only the mV write is flashing Push CAL to confirm the calibration The RACER COMPACT is in measure and dosin...

Page 32: ...in the system a reduction of this concentration could be determined by the wear of the squeezing tube which in this case must be replaced or by the clogging of the filter which must be cleaned as in t...

Page 33: ...ould the tube be swollen check tube material against our chemical resistance compatibility chart 2 Check clogging of the filter 3 Check clogging of the injection valve Electrical faults THE PUMP DOES...

Page 34: ......

Page 35: ......

Page 36: ...DISTRIBU PAR DISTRIBUTED BY DISTRIBUIDO POR CASH PISCINES 9 AVENUE DE LA GRANDE SEMAINE 33700 M RIGNAC FRANCE COD SDMU 00236ML1A 01 2023...

Reviews: