1260-00C User Manual
Operation 3-2
Table 3-1. 1260-00C Factory Configuration
Function
Factory Configuration
Start-Up Mode
488 VXI Runtime System Mode
VXIbus Characteristics
Resource Manager (RM)
Logical Address
Servant Area Size
Shared Memory
Address Modifiers
Enabled
0
0
0% of Installed Memory
Supervisor A16, Supervisor A24 Data
VXIbus Slot 0 Services
CLK10 Driver
CLK10 Source
SYSCLK Driver
Priority Arbiter
Bus Timeout
Enabled
Onboard Clock
Enabled
Enabled
Enabled (BTO
$
250µsec)
Bus Requester
Level 3
VXI Interrupt Handlers
Unassigned
GPIB Addressing Mode
Multiple Secondary Addressing
1260-00C GPIB Primary Address
1
Serial Port
System Start-Up Messages
Console Local Command Port
Discrete Fault Indicator (DFI)
Disabled
Enabled
Normally Open
Front Panel BNC Termination
External Clock Input
External Trigger Input
Unterminated
Unterminated
The 1260-00C factory configuration does not have to be changed
to use it as a Slot 0 Resource Manager. The following pages
describe the factory configuration settings, and present alternate
configurations.
Figure 2-1 shows the location of the 1260-00C configurable
components and their physical location relative to some of the
major circuit components. The jumpers and switches are
represented in their factory default positions.