64
Smartcat (BL2100)
A.1.1 Exclusion Zone
It is recommended that you allow for an “exclusion zone” of 0.25" (6 mm) around the
BL2100 in all directions when the BL2100 is incorporated into an assembly that includes
other components. This “exclusion zone” that you keep free of other components and
boards will allow for sufficient air flow, and will help to minimize any electrical or EMI
interference between adjacent boards. An “exclusion zone” of 0.12" (3 mm) is recom-
mended below the BL2100. Figure A-2 shows this “exclusion zone.”
Figure A-2. BL2100 “Exclusion Zone”
Power
9–36 V DC
*
, 1.5 W max. (without display), 3 W max. (with display)
Operating Temperature
–40°C to +70°C
Humidity
5–95%, noncondensing
Board Size
3.41" × 4.14" × 0.93"
(87 mm × 105 mm × 24 mm)
* 13 V to 36 V DC supply voltage required to support full 0–10 V DC output range of D/A converter
Table A-1. BL2100 Specifications (continued)
Feature
BL2100
BL2110
BL2120
BL2130
0.12
(3)
0.12
(3)
0.93
(24)
3.41
(87)
Exclusion
Zone
4.14
(105)
0.25
(6)
0.25
(6)
0.25
(6)
0.25
(6)
0.25
(6)
0.25
(6)
0.93
(24)
Summary of Contents for Smartcat
Page 6: ...Smartcat BL2100 ...
Page 14: ...8 Smartcat BL2100 ...
Page 60: ...54 Smartcat BL2100 ...
Page 78: ...72 Smartcat BL2100 ...
Page 84: ...78 Smartcat BL2100 ...
Page 118: ...112 Smartcat BL2100 ...
Page 124: ...118 Smartcat BL2100 ...
Page 132: ...126 Smartcat BL2100 ...
Page 134: ......