RabbitCore RCM3309/RCM3319
rn_sp_close
void rn_sp_close(int port);
DESCRIPTION
Deactivates the RCM3309/RCM3319 RabbitNet port as a clocked serial port. This call
is also used by
rn_init()
.
PARAMETER
portnum
= 0
RETURN VALUE
None.
rn_sp_enable
void rn_sp_enable(int portnum);
DESCRIPTION
This is a macro that enables or asserts the RCM3309/RCM3319 RabbitNet port chip
select prior to data transfer.
PARAMETER
portnum
= 0
RETURN VALUE
None.
rn_sp_disable
void rn_sp_disable(int portnum);
DESCRIPTION
This is a macro that disables or deasserts the RCM3309/RCM3319 RabbitNet port chip
select to invalidate data transfer.
PARAMETER
portnum
= 0
RETURN VALUE
None.