background image

Mode and Filter Reset 

Mood Light and Negative Ion Generator

Speed 

Power 

Filter Replacement Indicator

Pollen Mode Indicator

Fan Speed Indicator

Mood Light

Auto Mode Indicator

Sleep Mode Indicator

Ion Indicator

Air Quality Indicator

Control Panel

Indicator Lights

This is a dual control button. When 
pressed briefly, you can change the 
mode of operation between Auto 
Mode and Pollen Mode. When 
pressed and held, the Replace Filters 
Indicator will be reset.

This dual control button, when pressed 
briefly, will turn the Mood Light on or off. 
When pressed and held, the Negative Ion 
Generator will turn on or off.

There are five speeds. Operation speed

changes in the following order as you press

the speed button. 

Silent > Low > Medium > High > Turbo

Press and hold the power button for two
seconds to turn the unit on or off.

The Mood Light has four colors: blue,

purple, light purple and pink.

(Turbo)

(High)

(Medium)

(Low)

(Silent)

(Pollen)

(Replace

Filters)

(Auto)

(Ion)

(Sleep)

(Air Quality 

Indicator)

When Pollen Mode is selected, the 
fan speed of the air purifier 
changes automatically depending 
on the readings of the air quality 
sensors. The Mood Light shifts 
color in the following pattern: 
blue > purple > light purple > pink .

When this indicator lights up, it 
is time to replace  your filters.
Once the filters are replaced, 
press and hold the Mode/Filter 
Reset button to reset the 
Replace Filters Indicator.

When Auto Mode is selected, the 
fan speed of the air purifier 
changes automatically depending 
on the readings of the air quality 
sensors and light sensor. The 
Mood Light is solid blue when the 
unit is in Auto Mode.

This indicates that the 
Negative Ion Generator is 
operating.

This indicates that the unit is 
operating in Sleep Mode.

This light indicates the current air 
quality in the room. The colors will 
shift from blue > purple > light 
purple > red, depending on the 
amount of contaminants. Blue 
represents good air quality, while 
red represents poor air quality.

7

8

Indicates the fan speed of 
the air purifier. The lowest 
speed is Silent. The highest 
speed is Turbo. 

運転切替

フィルター

リセット

ムードライト

ターボ

静音

フィルター

交換

花粉

自動

マイナス

イオン

マイナスイオン

入/切

スリープ

光センサー

空気品質

インジケーター

ニオイセンサー

電源

風量

運転切替

ムードライト

Power

Speed

Mode

Mood Light

静音

フィルター
交換

花粉

自動

マイナスイオン

マイナスイオン

入/切

スリープ

光センサー

空気品質

インジケーター

ムードライト

フィルター
リセット

ターボ

ターボ

運転切替

風量

ターボ

静音

花粉

フィルター

交換

自動

マイナス

イオン

スリープ

空気品質

インジケーター

Summary of Contents for MinusA2 SPA-780J

Page 1: ...MINUSA2UMJP1601 0120 152 952 www rabbitair co jp SPA 780J...

Page 2: ...MinusA2 Rabbit Air MinusA2 Rabbit Air www rabbitair co jp MinusA2 Rabbit Air Rabbit Air Rabbit Air Rabbit Air Rabbit Air...

Page 3: ...Rabbit Air 100V Rabbit Air Rabbit Air Rabbit Air Rabbit Air Rabbit Air Rabbit Air Rabbit Air 60cm Rabbit Air Rabbit Air Rabbit Air Rabbit Air Rabbit Air Rabbit Air Rabbit Air CADR EPA EPA...

Page 4: ...Power Speed Mode Mood Light MinusA2...

Page 5: ...Power Speed Mode Mood Light...

Page 6: ...1 2 MinusA2 6 3 4 5 HEPA...

Page 7: ...6 7 8 BioGS HEPA 9 9 10...

Page 8: ...100V 3 100V 3 100V 5 3 100V 3 MinusA2 3...

Page 9: ...3 10 3...

Page 10: ...1 2...

Page 11: ...BioGSTM HEPA 1 2 BioGS HEPA HEPA 1 HEPA 2 3 HEPA 11 1 2 BioGS HEPA...

Page 12: ...MinusA2 Rabbit Air MinusA2 MinusA2 60cm 20cm www rabbitair co jp 0120 152 952 0120 152 952 Rabbit Air Rabbit Air MinusA2 Rabbit Air SPA 780J 9 1 kg 60 cm 20 cm 20 cm...

Page 13: ...MinusA2 0120 152 952 Rabbit Air 19 20 10 12 17 15 15 3 14 10 12...

Page 14: ...arranty Rabbit Air www rabbitair co jp warranty Rabbit Air Rabbit Air i ii Rabbit Air iii iv a Rabbit Air Rabbit Air b c d e Rabbit Air 0120 152 952 CS rabbitair co jp Rabbit Air Rabbit Air www rabbit...

Page 15: ......

Page 16: ...tended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning...

Page 17: ...nstructions The Rabbit Air puri er is designed for use in a 100V outlet only Turn o your Rabbit Air puri er before unplugging it from the power outlet Unplug the Rabbit Air puri er from the power outl...

Page 18: ...d Light Light Sensor Particle Sensor Air Quality Indicator Battery AAA size Power Mood Light Speed Mode Power Cord Bracket Holder Air Outlet Handle Meet your MinusA2 Front view Back view Remote contro...

Page 19: ...Auto Ion Sleep Air Quality Indicator When Pollen Mode is selected the fan speed of the air puri er changes automatically depending on the readings of the air quality sensors The Mood Light shifts colo...

Page 20: ...rd Lay the lter case on a at surface 3 Pull the tabs on the front of the Pre Filter to remove it 4 Remove the white Medium Filter from the black frame to discard the plastic wrapping Return the lter t...

Page 21: ...er Odor Remover Customized Filter Front color Purple Back color Black Front color Purple Orange Back color Orange Front color Purple Yellow Back color Yellow Front color Black coated material Back col...

Page 22: ...me illuminated When the unit is in Sleep mode the Mood Light and Air Quality Indicator will automatically turn o If the unit is operating in Auto Mode the fan speed of the air puri er will automatical...

Page 23: ...the Speed and Mode button for three seconds The Air Quality Indicator and Auto Mode Indicator will blink Press the Speed button to choose the sensitivity level Replace Filters Low sensitivity Pollen M...

Page 24: ...lter washing method 1 Remove the Pre Filter from the unit 2 Fill the sink with lukewarm water and gently wash the Pre Filter under the water for 2 3 minutes or until it is completely clean 3 Rinse the...

Page 25: ...and place in the black frame 3 Make sure the front of the Customized Filter is facing up See Customized Filter chart page 11 to identify the front of your speci c lter Do NOT discard the lter holder...

Page 26: ...ng wiring in the wall while installing the wall mount bracket Correct installation is extremely essential and falls outside the scope of responsibility of Rabbit Air Please consult a quali ed contract...

Page 27: ...latched on the hinges of the main unit Battery could be dead or depleted Remote might not be pointed directly at the unit Make sure the battery is correctly installed Filters may be heavily soiled and...

Page 28: ...e the lters should be replaced with authentic Rabbit Air replace ment lters as recommended in this manual Limited Warranty Within the rst 90 days of purchase Rabbit Air will replace the defective unit...

Reviews: