RAB STEALTH STL360 Instructions Manual Download Page 9

INSTRUCTIONS

STEALTH STL360 INSTALLATION

RAB Lighting is committed to creating high-quality, aff ordable, well-designed and energy-effi  cient LED lighting and controls that make it easy for electricians to install

and end users to save energy. We’d love to hear your comments. Please call the Marketing Department at 888-RAB-1000 or email: [email protected]

SENSOR MODES (

cont’d)

Manual Override Mode

The STL360 has a “protected” Manual Override that requires a 

double-fl ip of the light switch so momentary power problems 

do not interfere with normal sensor operation.

By fl ipping the switch that operates the sensor twice                      

(off -on-off -on)

 within 2 seconds you will override the sensor to keep 

lights on continuously until dawn.
If you set the Manual Override Mode during daylight, the 
sensor will be prepared to turn on at dusk and remain on until 
dawn. This is a handy feature if you leave home for the day and 
you want the lights on to greet you when you return. When the 
sensor is in “Ready for Manual Override Mode” the middle LED 
will be on as shown in Fig 27.

To Resume Automatic Mode

Switch OFF the power for at least 10 seconds then turn it ON again. 
Sensor will reset to Automatic Mode after completing the warm-
up period.

Daytime (24-Hour) Operation Of Manual Override

If you set Manual Override while the sensor is set to 24 hour 
operation

 (photocell set to MOON/SUN)

, lights will come on and 

remain on continuously. 

Lights will not turn off   at dawn.

Fig: 27

Fig: 28

WALK TESTING

“Ready for Manual Override Mode”

Middle LED on

STL360’s full coverage pattern reduces the need for aiming and 
adjustment. The purpose of the Walk Test is to check and adjust 
the coverage pattern. The STL360 must be manually set into 
Test Mode

 (Fig. 26).

To enter Test Mode

Turn Time setting to 5 seconds and turn off  sensor for 10 seconds.  
After a warm up period of 30 seconds the LEDs will be off .

1. 

Aim the sensor at the traffi  c pattern you want to detect. 

Sensor will detect any movement 

ACROSS

 its pattern 

most eff ectively.

2. 

Start outside the pattern 

(Fig 28)

 and walk across the pattern 

until the lights go on. As distance from the sensor increases, 
it will take more movement to be detected.

3. 

Adjust sensor aiming as necessary to improve coverage. 
Make sure sensor is level.

4. 

Sensitivity may be decreased with the SENS knob to detect 
a limited area or if the sensor is being activated by wind, 

foliage, traffi  c or animals, or increased to cover a larger area 

(see Fig. 20 to adjust sensor settings)

. The lens mask can also 

be used to drastically reduce coverage or allow undetected 
movement from some directions.

5. 

Repeat steps 1-4 until you are satisfi ed with coverage. 
Vacate the detection zone for 1 minute and then turn the 

settings back to desired time delay. Your sensor is now 
ready for operation.

Summary of Contents for STEALTH STL360

Page 1: ...or garage door openers Sensor functions best when the direction of expected movement is across its detection pattern not towards the sensor Mount 6 10 high for optimum range and detection WARNING RIS...

Page 2: ...ghts remain on as long as there is movement within the protection zone Once the zone is vacated lights can be adjusted to remain on approximately 5 seconds up to 12 minutes Since the lights are on onl...

Page 3: ...ge an area does STL360 protect Two powerful detectors combine to give the STL360 180 x 60 long forward range plus superb 360 downward detection below and to all sides as shown in Fig 3 Di cult locatio...

Page 4: ...mounted level from side to side and pointed at the area where you desire coverage If tilted part of the detection zone may be high in the air over people s heads as shown in Fig 12 Fig 8 Fig 11 Fig 1...

Page 5: ...location as shown in Fig 14 Mounting and Wiring Red pigtail is only used to switch remote or additional fixtures as shown in Fig 16 STL360 floodlight kits come pre wired and assembled on the RAB CU4 E...

Page 6: ...silicone sealant around plate and all openings to ensure a weather proof seal Seal all unused conduit entries on surface junction box 9 Install lamps Turn on power Conduct walk test to adjust sensor...

Page 7: ...ell For night only operation turn the knob completely counterclockwise to the MOON symbol For 24 hour operation turn the knob all the way clockwise to the MOON SUN symbol Adjust counterclockwise to ha...

Page 8: ...g 25 Fig 26 Evening Timer Mode Keeps lights on for 1 8 hours after dusk Sensor then reverts to Automatic Mode until dawn If you set the Evening Timer Mode during daylight the sensor will be prepared t...

Page 9: ...ual Override while the sensor is set to 24 hour operation photocell set to MOON SUN lights will come on and remain on continuously Lights will not turn o at dawn Fig 27 Fig 28 WALK TESTING Ready for M...

Page 10: ...below Solution 1 Aim sensor away from movement or 2 Mask lens in the direction of the source 3 Lower sensitivity control setting Lights Turn On and Off Inappropriately 1 Make sure that the sensor is i...

Page 11: ...The sensor s photocell may detect the light and deactivate daylight If you desire the sensor to operate in higher ambient light levels turn the SUN MOON control knob counter clockwise toward the sun s...

Page 12: ...l from side to side and pointed at the area you desire If unit is tilted part of the detection zone may be high in the air over people s heads Solution Position sensor exactly level from side to side...