RAB STEALTH STL360 Instructions Manual Download Page 7

INSTRUCTIONS

STEALTH STL360 INSTALLATION

RAB Lighting is committed to creating high-quality, aff ordable, well-designed and energy-effi  cient LED lighting and controls that make it easy for electricians to install

and end users to save energy. We’d love to hear your comments. Please call the Marketing Department at 888-RAB-1000 or email: [email protected]

STL360 KIT ASSEMBLY AND WIRING (

cont’d)

Multiple Sensors

Multiple sensors may be wired together, but doing this will make 

problems diffi  cult to troubleshoot. Single sensors that control their 

own lights will give a more accurate location of movement and 
trouble-free operation.

Multiple Fixtures

Multiple fi xtures may be wired to a single sensor. To handle loads 
greater than 1000 watts, a qualifi ed electrician should install a relay

as shown in Fig 19.

Fig: 19

Power Quality

It is not recommended to install sensors on a circuit that also feeds 
motor loads such as HVAC equipment, kitchen appliances, or ga-
rage door openers. The Stealth circuit is surge and transient voltage 
protected.

However, if voltage varies signifi cantly from 120V, the sensor may 

malfunction. This may occur on circuits with motor loads. 

Fig: 21

Fig: 22

Fig: 22

Fig: 20

Photocell

For night-only operation, turn the knob completely 
counterclockwise to the 

MOON

 symbol. For 24-hour operation turn 

the knob all the way clockwise to the 

MOON/SUN

 symbol. 

Adjust counterclockwise to have the sensor come on later at 
dusk, clockwise to have it come on earlier. The Factory Setting is 
Night-only

 (MOON)

. If you set Evening Timer while set to 24 hour 

operation, Evening Timer will begin immediately after fl ipping 

switch as shown in Fig 21.

Evening Timer

The STL360 provides an alternative to normal motion-activated 
lighting. The EVENING TIMER as shown in Fig 22 can keep lights 
on continuously without motion detected for 1 to 8 hours after 
dusk. This is great for evening activities requiring continuous light. 
During vacations the EVENING TIMER provides a “lived-in” look by 

simulating an occupant turning lights on at dusk, and then off  at 

bedtime.

Sensitivity

Increases or decreases the responsiveness and range of the 
sensor 

(adjustable from 30% to 100%).

 The Factory Setting is 

100% as shown in Fig 22.

Time

Sets the time that lights will remain on after the detection zone is 

vacated. Adjustable from approximately 5 seconds to 12 minutes. 
The factory setting is 12 minutes as shown in Fig 20.

ADJUSTING STL360 SETTINGS (

cont’d)

ADJUSTING STL360 SETTINGS

TIME

1           8 HRS

5 SECS          12 MINS

–         +

EVENING

  TIMER

SENS

TIME

1           8 HRS

5 SECS          12 MINS

–         +

EVENING

  TIMER

SENS

TIME

1           8 HRS

5 SECS          12 MINS

–         +

EVENING

  TIMER

SENS

Summary of Contents for STEALTH STL360

Page 1: ...or garage door openers Sensor functions best when the direction of expected movement is across its detection pattern not towards the sensor Mount 6 10 high for optimum range and detection WARNING RIS...

Page 2: ...ghts remain on as long as there is movement within the protection zone Once the zone is vacated lights can be adjusted to remain on approximately 5 seconds up to 12 minutes Since the lights are on onl...

Page 3: ...ge an area does STL360 protect Two powerful detectors combine to give the STL360 180 x 60 long forward range plus superb 360 downward detection below and to all sides as shown in Fig 3 Di cult locatio...

Page 4: ...mounted level from side to side and pointed at the area where you desire coverage If tilted part of the detection zone may be high in the air over people s heads as shown in Fig 12 Fig 8 Fig 11 Fig 1...

Page 5: ...location as shown in Fig 14 Mounting and Wiring Red pigtail is only used to switch remote or additional fixtures as shown in Fig 16 STL360 floodlight kits come pre wired and assembled on the RAB CU4 E...

Page 6: ...silicone sealant around plate and all openings to ensure a weather proof seal Seal all unused conduit entries on surface junction box 9 Install lamps Turn on power Conduct walk test to adjust sensor...

Page 7: ...ell For night only operation turn the knob completely counterclockwise to the MOON symbol For 24 hour operation turn the knob all the way clockwise to the MOON SUN symbol Adjust counterclockwise to ha...

Page 8: ...g 25 Fig 26 Evening Timer Mode Keeps lights on for 1 8 hours after dusk Sensor then reverts to Automatic Mode until dawn If you set the Evening Timer Mode during daylight the sensor will be prepared t...

Page 9: ...ual Override while the sensor is set to 24 hour operation photocell set to MOON SUN lights will come on and remain on continuously Lights will not turn o at dawn Fig 27 Fig 28 WALK TESTING Ready for M...

Page 10: ...below Solution 1 Aim sensor away from movement or 2 Mask lens in the direction of the source 3 Lower sensitivity control setting Lights Turn On and Off Inappropriately 1 Make sure that the sensor is i...

Page 11: ...The sensor s photocell may detect the light and deactivate daylight If you desire the sensor to operate in higher ambient light levels turn the SUN MOON control knob counter clockwise toward the sun s...

Page 12: ...l from side to side and pointed at the area you desire If unit is tilted part of the detection zone may be high in the air over people s heads Solution Position sensor exactly level from side to side...

Reviews: