RAB STEALTH STL360 Instructions Manual Download Page 5

INSTRUCTIONS

 

STEALTH STL360 INSTALLATION

RAB Lighting is committed to creating high-quality, affordable, well-designed and energy-efficient LED lighting and controls that make it easy for electricians to install

 

and end users to save energy. We’d love to hear your comments. Please call the Marketing Department at 888-RAB-1000 or email: [email protected]

INSTALLATION (

cont’d)

Fig: 13

Fig: 16

Locate for Movement Across Pattern

 

Check that movement is not directly towards sensor. Sensor is more 
sensitive 

ACROSS

 its pattern

 (Fig 13)

. Check that movement far 

away and directly towards sensor is not entirely within one zone. To 
fix, change the sensor angle or location as shown in Fig 14.

Mounting and Wiring

 

Red pigtail is only used to switch remote or additional fixtures

 

as shown in Fig 16.

STL360 floodlight kits come pre-wired and assembled on the 

 

RAB CU4 EZ Plate

 allowing for mounting on round, rectangular  

or octagonal surface or recessed boxes.

Fig: 14

Fig: 15

Choose a Protected Location

 

Mount sensor in protected area. The more protected the mounting 
location, the less chance of lights turning on occasionally during 
rain, snow and windstorms. This could happen because the sensor 
is detecting dramatic changes in temperature as shown in Fig 15. 

More sensitive

Less  

sensitive

Better detection after

“micro adjustment”

WRONG

OK!

STL360 KIT ASSEMBLY AND WIRING

Insert 

close-up

plug in 

unused 

hole

Finishing 

Cap

Bar Screws

Gasket &

Surface Plate

Universal

Mounting

Bar

Hook

O-Ring

Gasket

CU4 EZ Plate

Gasket

Center

Screw

Summary of Contents for STEALTH STL360

Page 1: ...or garage door openers Sensor functions best when the direction of expected movement is across its detection pattern not towards the sensor Mount 6 10 high for optimum range and detection WARNING RIS...

Page 2: ...ghts remain on as long as there is movement within the protection zone Once the zone is vacated lights can be adjusted to remain on approximately 5 seconds up to 12 minutes Since the lights are on onl...

Page 3: ...ge an area does STL360 protect Two powerful detectors combine to give the STL360 180 x 60 long forward range plus superb 360 downward detection below and to all sides as shown in Fig 3 Di cult locatio...

Page 4: ...mounted level from side to side and pointed at the area where you desire coverage If tilted part of the detection zone may be high in the air over people s heads as shown in Fig 12 Fig 8 Fig 11 Fig 1...

Page 5: ...location as shown in Fig 14 Mounting and Wiring Red pigtail is only used to switch remote or additional fixtures as shown in Fig 16 STL360 floodlight kits come pre wired and assembled on the RAB CU4 E...

Page 6: ...silicone sealant around plate and all openings to ensure a weather proof seal Seal all unused conduit entries on surface junction box 9 Install lamps Turn on power Conduct walk test to adjust sensor...

Page 7: ...ell For night only operation turn the knob completely counterclockwise to the MOON symbol For 24 hour operation turn the knob all the way clockwise to the MOON SUN symbol Adjust counterclockwise to ha...

Page 8: ...g 25 Fig 26 Evening Timer Mode Keeps lights on for 1 8 hours after dusk Sensor then reverts to Automatic Mode until dawn If you set the Evening Timer Mode during daylight the sensor will be prepared t...

Page 9: ...ual Override while the sensor is set to 24 hour operation photocell set to MOON SUN lights will come on and remain on continuously Lights will not turn o at dawn Fig 27 Fig 28 WALK TESTING Ready for M...

Page 10: ...below Solution 1 Aim sensor away from movement or 2 Mask lens in the direction of the source 3 Lower sensitivity control setting Lights Turn On and Off Inappropriately 1 Make sure that the sensor is i...

Page 11: ...The sensor s photocell may detect the light and deactivate daylight If you desire the sensor to operate in higher ambient light levels turn the SUN MOON control knob counter clockwise toward the sun s...

Page 12: ...l from side to side and pointed at the area you desire If unit is tilted part of the detection zone may be high in the air over people s heads Solution Position sensor exactly level from side to side...